Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - GYS STARTPACK PRO 12.24 XL Betriebsanleitung

Vorschau ausblenden Andere Handbücher für STARTPACK PRO 12.24 XL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18

TROUBLESHOOTING

Symptoms
The STARTPACK PRO 12.24 XL
does not start :
The red led is on.
Alarm beep.
The STARTPACK PRO 12.24 XL
does not start :
No led is on.
No alarm beep.
The GYSFLASH 6.12 XL's green led
is on.
The GYSFLASH 6.12 XL's orange
led is on.
The voltage selector's leds blink
alternatively.
The GYSFLASH 6.12 XL's green led
is on.
The STARTPACK PRO 12.24 XL
does not enter charge mode.
BATTERY NOT COVERED BY THE WARRANTY
The STARTPACK PRO 12.24 XL works with two 12V high performance batteries which MUST be recharged after each
use. If this recommendation is not followed, the batteries may permanently deteriorate.
For this reason, the STARTPACK PRO 12.24 XL batteries are not covered by the warranty.
STARTPACK PRO 12.24 XL
Causes
The voltage selector is unplugged.
The selected voltage is not adap-
ted to the vehicle.
Polarity reversal
The battery voltage is < 4V.
The vehicle requires too much
starting current.
The batteries are faulty.
Several start attempts without
waiting between each attempt.
The charge is in progress.
The voltage selector is unplugged.
The connection is interrupted.
Remedies
Plug the selector on 12V or 24V
depending on the vehicle to start.
Check the battery polarity. Red
clamp to the battery's (+) and
black clamp to the battery's (-).
Put the STARTPACK PRO 12.24 XL
on charge.
Put the STARTPACK PRO 12.24
XL on charge to attempt a battery
recovery.
Wait 3 minutes between
each start attempt.
Let the batteries rest.
Wait for the
STARTPACK PRO 12.24 XL's green
led
to switch on.
Set the voltage selector on 12V for
an optimal charge.
Check the
GYSFLASH 6.12 XL's power sup-
ply as well as the charging cable
connected to the STARTPACK PRO
12.24 XL.
EN
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis