Diagnostic display

Number State
The operator starts up and
"0"goes out.
Garage door has reached end
position OPEN.
Garage door has reached end
position CLOSE.
End position has not been
reached.
The display shows a "0" during
the next opening and closing
cycle and then goes out.
The display continues to show a
"0".
The door does not open or close. Interruption at STOP A or activation of an external safety device
The door does not close.
The door setting and learning
cycle did not complete correctly.
There is a permanent impulse
signal at the start input.
An error occurred in setting the
operator.
Visual closing edge protection
OSE or electrical contact strip 8k2
has tripped.
Error in learning cycle.
The door does not open or close. An error occurred during the self-test. Disconnect the power
Motor standstill.
Electronic brake activated. The
garage light remains on.
The vacation lock is activated.
The door does not open.
B-1200
Diagnosis / Remedy
In normal operation, drive receives start signal via START input or
by drive unit.
The operator is carrying out a learning cycle for the force limit.
Caution: During this travel cycle the operator does not monitor the
force. Make sure that no persons or objects are in the travel path
of the garage door.
The force-learning cycle did not complete and must be repeated.
The door's end-of-travel position may have too much pressure.
Set the door's pressure to the correct level.
(such as a pass-door).
Interruption at STOP B or activation of an external safety device
(such as a photoelectric sensor).
You must use menu stages 3 and 4 to complete the door settings
correctly and then complete the force-learning cycle.
Start signal is not detected or pulse duration (eg button jammed).
The travel path is too long.
Repeat setting procedure with menu stages 3 and 4.
Check the connection/wiring.
Repeat position learning cycle with menu stages 3 and 4.
Reduce force when approaching the end-of travel positions.
supply.
The motor does not rotate. Call a specialist company to repair the
motor.
The drive is pulled from the upper end position. Check the door
and the springs. Setting upper end lower.
The side switch for SafeControl/Signal 112 is active. A reset is
required.
Diagnostic display
51