Menu 5 + Menu 6:
Force limitation for Open and Close.
Warning:
If the setting is too high, persons may be placed at risk of injury.
In the delivery state, the set value is '6' when opening and '4' when closing. We recommend selecting
the appropriate door type in menu 8 before the force learning cycle.
1. Select menu item "5".
After about 2 seconds, the display blinks and the set value of the power limit for upward motion appears.
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
3. Press the programming button (PROG button) (D).
The display shows "6". After about 2 seconds the display and the set value for the power limit for closure
appears.
4. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Warning:
The force on the main closure side must not exceed 400 N / 750 ms!
5. Press the programming button (PROG button) (D).
The display shows "7".
Menu 7:
Adjust the light phases
1. Select menu item "7".
After about 2 seconds the display blinks and the set value for light time appears.
The factory setting is "0"
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Menu value
0
1
2
3
4
5
6
7
8
9
Remarks:
With the pre-warning time set, the light relay K engages before the drive starts and during the run.
Warning:
Use self-flashing signal lamp.
3. Press the programming button (PROG button) (D).
The display shows "8".
B-1200
Light time
60 s
120 s
240 s
0 s
0 s
0 s
0 s
90 s
90 s
0 s
Warning time
0 s
0 s
0 s
0 s
3 s
0 s
3 s
3 s
3 s
8 s
Installation
Flashing function
No
No
No
Yes
No
No
Yes
No
Yes
Yes