Maintenance

Cleaning the condensate receptacle

Cleaning and refilling the syphon

Inspection of combustion chamber

1
3
2
5
Cleaning the condensate receptacle
Disconnect the plug of the fluegas
temperature sensor (1);
Remove the internal fluegas pipe (2)
of the boiler in order to create access
to the condensate receptacle;
Clean the receptacle (3);
Mount the fluegas pipe back in
position when the cleaning is finished;
Connect the plug of the fluegas
temperature sensor.
Cleaning and refilling the syphon
Remove the syphon (4) from the
condensate connection;
Clean and fill it with fresh water;
Mount the syphon back in the original
position.
Inspection of combustion chamber
The sight glass (5) is positioned on the
left hand side of the boiler.
Inspect the combustion chamber by
viewing through the sight glass.
Cleaning can be done with water:
Remove the viewing mirror and glass
from the sight glass holder;
Stick a garden hose through the sight
glass holder and rinse the heat ex-
changer with water;
Reassemble the sight glass.