The device associated with this operating manual contains 2
AAA Alkaline batteries (1.5V) in delivery condition. These bat-
teries are not made for recharging. The use of a rechargeable
battery is not possible with this device and can damage it. If
the included batteries are depleted, they must not be thrown
into the household waste. Used batteries may contain harmful
substances that can cause environmental or health damage.
Please return all depleted batteries to electrical appliance
stores, who collect them for free.
Battery exchange
To replace the batteries, push the battery cover on the rear of
the unit downwards and replace the discharged batteries with
new ones. Be aware of the polarity when inserting the batteries
(+/- pole). Close the battery compartment cover again. In the
EU the return of used batteries is mandatory by law. All deple-
ted batteries and also rechargeable batteries will be recycled.
This way valuable resources like iron, zinc and nickel can be
retrieved and are reusable then. Battery recycling is the easiest
lesson in environmental protection – so please support it!
The shown garbage bins mean that batteries or rechargeable
batteries must not be thrown into the household waste. The
signs below the garbage bins are acronyms for the chemical
substances inside the battery:
23
Hg: Battery contains Mercury
Cd: Battery contains Cadmium
Pb: Battery contains Lead
Technical data*
Sensor
Fuel Cell sensor
Accuracy
+/- 0.075‰ (per mill) with reference
to 1.00‰ at 25°C (per mill = default
setting)
OR +/- 0.0075% BAC (Blood Alcohol
Concentration) with reference to 0.100
% BAC at 25°C
OR +/- 0.0375mg/l with reference to
0.50mg/l at 25°C
Detection Range
0.00 up to 4.00‰ (‰ = default
setting)
OR 0.000 up to 0.400% BAC (USA)
OR 0.00 up to 2.00mg/L (UK)
Warm-up Time
Within 15 - 20 seconds at 0.5‰, it may
vary depending on the value of per
mill / BAC which was measured
Dimension
109 x 51 x 18mm (L x W x H)
Weight
84g (battery included)
Power Supply
2 pieces of 1.5V AAA Alkaline batteries
(= energy for up to 1000 tests)
Working Temper-
5°C up to 40°C
ature
Storage Temper-
0°C up to 40°C
ature
Calibration
Every 12 months or after 500 tests.
For a calibration service you can send
the device to ACE Instruments (see
www.alkomat.net).
** The technical data are subject to change without prior notice