7.2 Air fi lter
In this connection, please also read the service
information.
Clean the air filter at regular intervals, and
replace it if necessary.
Open both clips (Fig. 11/A) and remove the air
filter cover (Fig. 11/B).
Remove the filter elements (Fig. 12/C)
Do not use abrasive cleaning agents or petrol
to clean the elements.
Clean the elements by tapping them on a flat
surface. In cases of stubborn dirt first clean
with soapy water, then rinse with clear water
and air-dry.
Assemble in reverse order
7.3 Spark plug (Fig. 13-14)
Check the spark plug for dirt and grime after 20
hours of operation and if necessary clean with a
copper wire brush. Thereafter service the spark
plug after every 50 hours of operation.
Open the maintenance flap (Fig. 13/E).
Pull off the spark plug boot with a twist.
Remove the spark plug (Fig. 14/D) with the
supplied spark plug wrench.
Assemble in reverse order
7.4 Changing the oil and checking the oil le-
vel (before using the machine)
The motor oil is best changed when the motor is
at working temperature.
Place the generator on a slightly inclined sur-
face so that the oil drain plug is at the lower
end.
Open the oil filler plug.
Open the oil drain plug and let the hot engine
oil drain out into a drip tray.
After the old oil has drained out, close the oil
drain plug and place the generator on a level
surface again
Fill in engine oil up to the top mark on the oil
dip stick.
Important: Do not screw the dipstick in to
check the oil level, simply insert it up to the
thread.
Dispose of the waste oil properly.
7.5 Automatic oil cut-out
The automatic oil cut-out responds if there is too
little oil in the engine. In this case it will not be
possible to start the engine or it will cut out auto-
matically after a short period of time. It cannot be
started again until the engine oil has been topped
up (see point 7.4).
Anl_TC-PG_5500_WD_SPK9.indb 23
Anl_TC-PG_5500_WD_SPK9.indb 23
GB
7.6 Changing a defective fuse
Open the fuse holder (Fig. 16a/Item A) and repla-
ce the defective fuse (Fig. 16b) with a new one.
Caution! Use only fuses of the same type previ-
ously installed in the respective fuse holder.
Pay attention in particular to the maximum current
strength (engraved in the fuse).
If you have any doubt, please contact our Custo-
mer Service or a qualifi ed electrician.
7.7 Maintenance
There are no parts inside the equipment
which require additional maintenance.
7.8 Storage
Leave the machine to cool (approx. 5 minu-
tes).
Clean the exterior housing of the machine.
Store the machine in a cold, dry place where
it is out of the reach of ignition sources and
inflammable substances.
7.9 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info

8. Disposal and recycling

The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should be
taken to a suitable collection center for proper dis-
posal. If you do not know the whereabouts of such
a collection point, you should ask in your local
council offi ces.