18
www.aeg.com
Problem
The dishes are wet.
13. TECHNICAL INFORMATION
Dimensions
Electrical connection
Water supply pressure
Water supply
Capacity
Power consumption
Power consumption
1) Refer to the rating plate for other values.
2) f the hot water comes from alternative source of energy, (e.g. solar panels, aeolian energy), use the
hot water supply to decrease energy consumption.
14.
GARANTIE, GARANZIA, GUARANTEE
CH
Kundendienst, service-clientèle,
Servizio clienti, Customer Service
Centres
Servicestellen
5506 Mägenwil/
Zürich Industries-
trasse 10
Refer to "Hints and tips" for
other possible causes.
1)
Points de Service
3018 Bern Morgen-
strasse 131
Possible solution
• The programme does not have a drying phase or has
a drying phase with low temperature.
• The rinse aid dispenser is empty.
• The quality of the rinse aid can be the cause.
• The quality of the multi-tablets can be the cause. Try a
different brand or activate the rinse aid dispenser and
use rinse aid and multi-tablets together.
Width / height / depth (mm) 596 / 818 - 898 / 575
Voltage (V)
Frequency (Hz)
Min. / max. bar (MPa)
Cold water or hot water
Place settings
Left-on mode (W)
Off-mode (W)
Servizio dopo ven-
dita
1028 Préverenges Le
Trési 6
220 - 240
50
0.5 (0.05) / 8 (0.8)
max 60 °C
2)
15
0.99
0.10
Point of Service
6928 Manno Via Vio-
lino 11