Service

With cleaning and maintenance on the machine, the
power cable should be disconnected from the supply.
Fluids should not come into contact with the motor.
When cleaning with fl uids the motor should be co-
vered to anoid contact.
The fi ne fi lter should be changed at least once per
year. Use only original spare parts. The microfi lter
should be changed every 300 running hours. Use
breathing protection during a filter change. The
operation should be performed in a closed area. Used
fi lters should be sealed in a plastic sack and disposed
of properly.
Check regularly that the electrical cable is not da-
maged.
The DC 3800c Twin should be performance tested
at least once per year because it may be used with
hazardous materials. Worn parts must be replaced.
Never compromise the function of the DC 3800c,
use only original spare parts.

Accessories

Description
Coupling socket
Coupling socket
Plastic sack, standard
Microfi lter
Fine fi lter, polyester,
with integrated fi lter cover
Warranty
The warranty period for this machine is two years
and covers manufacturers faults. The warranty is
valid under the condition that the machine is used
under normal conditions on the task for which it was
designed and is maintained properly. Normal wear is
not covered by this warranty.
Filterchange HEPA fi lter:
1.
4.
Part no
Description
2107
Fine fi lter cellulose, with
2129
integrated fi lter cover
4110
42024
42025
Other accessories — see Dustcontrol
catalogue.
Service performed by other than Dustcontrol or its
authorized agent voids automatically the warranty.