RF RW SW868/915/917/922-NET(-ESD)
//
Montage- und Anschlussanleitung / Regalsensor
Mounting and wiring instructions / Rack sensor
English
CAUTION
Battery acid. Material damage! Non-observance
may lead to functional impairment. Check porta-
ble batteries regularly for leaking. If the batteries
should leak, do not touch the leaked fluid with bare
hands. Wipe away any leaked fluid thoroughly using
a soft cloth.
Once the seal has been removed, the integrated batteries have a
maximum lifetime of 10 years. This is made possible by the extremely
low-power sleep mode. In sleep mode, power consumption is no high-
er than battery self-discharge.
Lifetime according to switching frequency
Normal
switching fre-
quency
Transmission
12x/h
impulses
= total per year
105,000
Lifetime
max. 10 yrs
In order to increase battery lifetime, we recommend the following
measures:
- Start operation of new devices immediately, plan stockpiling
of devices.
- Maintain constant operational temperature and humidity (around
20°C and dry).
- Set wake-up signal / status monitoring interval to be as long as
possible (e.g. > 1 x/h).
- Reduce actuation frequency (e.g. < 12 x/h).
- Do not move the device unnecessarily.
- Maintain constant storage temperature and low humidity
(+10 °C ... +20°C, dry).
Maintenance / Cleaning
=
DANGER
Live parts. Electrocution hazard!
Non-observance may lead to severe or fatal inju-
ries. Do not attempt to repair damaged or faulty
devices. All replacements must be carried out by
qualified staff.
High
Extremely
switching
high
frequency
switching
frequency
1x/min
6x/min
525,000
3,100,000
approx. 9 yrs
approx. 4 yrs
5 / 16
=
DANGER
Live parts. Electrocution hazard!
Non-observance may lead to injuries. Do not clean
device with water. Observe certified protection class
when cleaning.
We recommend the following regular maintenance steps, especially if
mobility of the device is restricted:
1. Remove dirt.
Clean enclosure on the outside only. Clean enclosure with household
cleaning agents. Do not use compressed air to clean.
Shutdown / storage / disposal
=
CAUTION
Live parts. Electrocution hazard!
Non-observance may lead to injuries. Do not at-
tempt to use a device which has
been disassembled.
=
CAUTION
Moving mechanical parts. Crushing hazard!
Non-observance may lead to injuries. Remove
holder with care.
Avoid overlong storage of the device.
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately. Dispose of possibly contained bat-
teries correctly.
Notice
We reserve the right to make design changes in line with technological
progress. Modifications to existing switches are not permitted. steute
accepts no liability for recommendations given or implied by these
instructions for use. No new guarantee, warranty or liability claims
beyond the steute general terms and conditions can be inferred from
these instructions for use.