HT10 - HT11 - HT20
tube are available (see figure 2).
7 - HT10 line lighted top cover option: to change cover
arrangement remove the screws and turn the upper
section (with the picture) of the cover in the opposite
direction, leaving the bottom section in the same position.
Replace screws.
5. 3 CLEANING AND SANITIZING
PROCEDURES
Cleaning and sanitizing of the dispenser are recommended to
guarantee the conservation of the best product taste and the
highest unit efficiency. This section is a procedural guideline
only and is subject to the requirements of the local Health
Authorities.
Prior to the disassembly and cleaning, the machine must be
emptied of product.

5. 3. 1 DISASSEMBLY

ATTENTION
Before any disassembly and/or cleaning procedure
make sure that the dispenser is disconnected from its
power source by unplugging it or switching off the 2-
pole wall breaker.
1 - Remove cover from the bowl.
2 - HT11 - HT20 PS lines: remove pump assembly from its
bowl location by turning (1) clocwise and lifting it up (2)
(see figure 4).
Dismantle spray tube and L-shaped tube. Take impeller
and bearing pin away from pump housing by removing the
14
figure 2
retaining pin.
3 - HT10 - HT 20 Mlines: remove stirrer by lifting up.
4 - Remove the empty bowl by lifting its faucet side up and off
cooling dome.
5 - Remove the bowl gasket.
6 - See 5.3.2 FAUCET DISASSEMBLY paragraph.
7 - Slide drip tray out and empty it.

5. 3. 2 FAUCET DISASSEMBLY

5. 3. 2. 1 HT11 - HT20 LINES WITH PINCH TUBE
FAUCET
1 - Push (1) the dispensing handle and remove (2) the pinch
tube from its vertical seat in the bowl bottom (see figure 4).
2 - Take the bowl away from the machine and turn it upside
down. Pull (1) the tab release lever and at the same time,
turn (2) to the left (counterclockwise) the faucet body till it
gets free, together with faucet cover, from the bowl (see
figure 5).