Installation Instructions
Installation and repair jobs on the heater are only to be
carried out by an expert. Read and follow the installation
instructions carefully prior to starting any work!
Caution
Despite careful manufacture, the heating system
may contain sharp-edged components, and
protective gloves should always be worn when
carrying out any maintenance or cleaning work.
Intended use
The Trumatic S 3002 FS liquid gas heater has been designed
for stationary installation in fixed awning structures. Operat-
ing the heater will only be allowed using 30 mbar LPG- supply
from the caravan or motorcaravan (e.g. via BBQ point).
The equipment must not be used in vehicles (campers)
or coaches.
The heater has a combustion air / exhaust circuit that is sealed
from the installation area.
Other applications are only permitted after prior consultation
with Truma.
Regulations
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
– modifications to the unit (including accessories),
– modifications to the exhaust duct and the cowl,
– failure to use original Truma parts as replacement parts and
accessories,
– failure to follow the installation and operating instructions.
The 30 mbar gas supply operating pressure must correspond
with the operating pressure of the device (see data plate).
For safety reasons we generally recommend having the op-
eration and the tightness of the gas system checked every
2 years by a specialist (e.g. expert in accordance with G 607).
In other countries the applicable technical and administra-
tive regulations must be observed.
More information on the regulations in the relevant destina-
tion countries can be requested from our foreign representa-
tives (see Truma Service Booklet or www.truma.com).
Approval
Declaration of conformity
The liquid gas heater Trumatic S 3002 FS has been approved
by the DVGW and complies with the EC guide lines
(90/396/EWG) for gas appliances as well as with the associ-
ated EC guidelines. The product ID No. for EU countries is
CE-0085AP0325
EC Type Approval
e1 032603
Choice of location
The heater is installed free-standing next to a fixed outer wall
and must be firmly secured with 6 screws. If the awning does
not have a fixed structure the outer wall must be reinforced
with a suitable additional structure.
The flue gas pipes and the cowls must be installed such that
flue gas cannot penetrate the interior.
14
If a Truma Ultraheat electric auxiliary heater is installed,
remove the relevant pre-cut cover and pre-install it in the
installation box as described in the installation instructions
enclosed with the Ultraheat. Please follow the instructions
in "Electrical Connection – Cable Routing" when routing the
cable.
Leadthrough for combustion air intake
and flue gas discharge
The combustion air is drawn in from the outside through the
side wall via a flexible dia. 80 mm hose immediately behind
the heater. The combustion air must not be drawn in
from the interior!
The leadthrough for the flexible hose of the combustion
air intake connection must be drilled at the prescribed
minimum height of 400 mm (distance between middle of hole
and floor at installation location)!
Provisionally place heater at
planned installation location
and mark outlines on the
wall. Remove heater, mark
holes for flue gas pipe dia.
70 mm (1) and combustion
air intake dia. 83 mm (2) as
shown in illustration and drill
holes. Line cavities in vicinity
of drilled holes with wood.
If the walls are of a
thicker type, drill flue
gas pipe leadthrough hole
upwards at an angle of
30 degrees so that flue gas
pipe can be routed with the
smallest possible radius.
Combustion air intake pipe routing
1. Make combustion air intake pipe (1) by cutting a piece of
pipe approx. 500 mm in length from the enclosed dia. 80 mm
pipe (1).
2. Slide rubber seal (3) over pipe (1) and insert pipe firmly onto
flange (4). Then secure pipe with 2 screws (8 – pre-drill by
2.5 mm!).
3. Insert pre-assembled pipe through the hole (2) from the
outside and attach with 4 screws B 3.5 x 13 (7) together with
the filter (5) and the cowl disk (6).
2
The pipe is sealed by the provided rubber seal – no additional
sealing required.
375 mm
75 mm
Ø 70
1
3
8
4
5
6
30°
7