Servicing
In the event of a fault contact the Truma Service outlet in the
first instance (see Truma Service Booklet or www.truma.com).
Caution
Despite careful manufacture, the heating system may
contain sharp-edged components, and protective
gloves should always be worn when carrying out any
maintenance or cleaning work.
Removing the heater front case
Pull the front case forward
at the top, lift up the retain-
ing springs and fold out front
case forwards.
Then disconnect the connect-
ing cables (e.g. for the warm
air fan and the ignition indica-
tor lamp).
For assembly, place the front
case on the lower retaining
lugs (p) and attach the electri-
cal connecting cables. Insert
operating bar into handle
sleeve from below and allow
front case to engage at the
top.
Press the control knob into
position from above in such a
way that the arrow points to
the "0" position.
Changing batteries on the automatic ignitor
If no ignition sparking can be heard, or only at intervals of
more than one second (or if the monitor lamp "e", a acces-
sory, is not flashing), the battery needs to be replaced.
Always ensure that heater is switched off and cooled down
before replacing battery. Insert a new battery before the start
of the heating season!
Remove the heater front case (see above),
push the battery compartment front case
up and change the battery. Ensure that
the polarity is correct. Close the battery
compartment again.
Only use temperature resistant (+70 °C), leakproof Mignon
batteries (LR 6, AA, AM 3, part no. 30030-99200), other bat-
teries could caus operational faults!
Cleaning
(only when device has been switched off and has cooled down!)
It is recommended that at least once a year, before the start
of the heating season, the dust should be removed which
may have collected on the heat exchanger, the baseplate, and
the fan wheel of the Truma vent hot air system. Clean the fan
wheel carefully with a dusting brush or small paintbrush.
12
General safety notes
If the gas system is leaking or if there is a smell of gas:
– extinguish all naked flames
– do not smoke
– switch off the appliances
– shut off the gas cylinder
– open windows and door
– do not actuate any electrical switches
– have the entire system checked by an expert!
A new O-ring must always be installed after dismantling the
exhaust duct!
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
– modifications to the unit (including accessories),
– modifications to the exhaust duct and the cowl,
– failure to use original Truma parts as replacement parts and
accessories,
– failure to follow the installation and operating instructions.
The operating pressure for the liquid gas supply is 30 mbar
must correspond to the operating pressure of the appliance
(see data plate).
For safety reasons we generally recommend having the op-
eration and the tightness of the gas system checked every
2 years by a specialist (e.g. expert in accordance with G 607).
During the initial operation of a brand new appliance (or after
it has not been used for some time), a slight amount of fumes
and smell may be noticed for a short while. This can be rem-
edied by running the heater immediately at maximum output
and ensuring adequate room ventilation.
p
If the burner makes an unusual noise or if the flame lifts off, it
is likely that the regulator is faulty and it is essential to have it
checked.
Repairs may only be carried out by an expert!
In other countries the applicable technical and admin-
istrative regulations must be observed.