Sicherheitshinweise • safety instructions • Informations sur la sécurité • Información de seguridad • Indicazi-
oni generali di sicurezza • Veiligheidsinstructies • Ogólne zasady bezpieczeństwa • Genel Güvenlik Uyarıları
The extraction forces express the force necessary to extract a screw
from the wall. Here it will not be distinguished if the screw comes out
of the wall with the plug, if the screw or the masonry breaks.
The extraction forces declare how strongly screws and / or plugs can
be vertically strained. The fixing material must be determined on the
basis of the mounting surface, the kind of assembly and the extracti-
on forces.
The awning has a wind resistance class 2 and must
be retracted in case the wind force is higher than 5.
The following chart explains the classes and shows the
wind speed and its effects.
Klasse
Wind force
Wind speed
0
1 -3
up to 19 km/h
1
4
20 - 28 km/h
2
5
29-38 km/h
3
6
39 - 49 km/h
Instructions for the assembler and the user:
All the operating instructions, assembly instructions as well as adjust-
ment instructions of the manufacturer of the motor, of the switcher
and of the control must be given to the user with a guide.
He must be comprehensively informed about the safety information
and user instructions of the awning. Failure to observe this informa-
tion and incorrect operation may cause damage to the awning and
accidents. The instructions must be kept and must be handed to the
new owner in case of the awning is given to a third. According to the
knowledge of the local conditions and of the executed assembly, the
installation company declares to the user if the wind resistance class
indicated by the manufacturer has been achieved in mounted con-
dition. If not, the installation company must document the actually
achieved wind resistance class.
The user and the assembler shall be responsible for proper functio-
ning of the wind monitoring system and its regular check and function
monitoring. In case of storm damage occurred in spite of wind mo-
nitoring, the supplier and manufacturer of the awning do not accept
any warranty. Sensors with sun monitoring must be turned off over
the winter.
In case of improper use the risk of injury is higher:
- Instruct all the people in using the motor and the controls safely.
Please monitor the moving awning and keep away people until the
movement is over
- Do not allow children to play with fixed or remote controls.
- Please keep the hand transmitter so that any undesired operation,
e.g. by means of playing children is excluded.
- Carry out maintenance and cleaning work on the awning exclusively
in absence of voltage.
In case of permanently installed devices, in compliance with DIN VDE
0700, an energy-isolation device for each phase must be present on
the part of the installation.
As energy-isolating devices, switches with a contact opening width of
min. 3 mm (e.g. Miniature Circuit Breaker or Residual Current Ope-
Effects
Leaves and thin twigs
move
Twigs and thin branches
move, loose paper is lifted
from the floor
Branches move and small
deciduous trees fluctuate
Thick branches fluctua-
te, umbrellas used with
difficulty
rated Circuit-Breaker) count. Please check the installation regularly.
In case of damage (e.g. signs of deterioration, damaged cables, and
misplaced end positions) the system is not allowed to be used
Note for the electrician:
This awning is not allowed to be connected under voltage. Turn off
the circuit breaker in advance! The system must be secured by means
of a residual current operated circuit-breaker in compliance with VDE.
For the electrical connection, it is allowed to use exclusively cables
and plug connections with a protection class of at least IP 54

Technical data

Motor type:
Voltage:
Frequency:
Rotational speed:
Current consumption:
Power:
Operating time:
Torque:
Emission sound pressure:
Connection & start-up:
Connect the motor according to the connection instructions. To pre-
vent that water penetrates the motor, the connection cable should be
always laid downwards with a loop.
Care and maintenance:
The awning is basically maintenance-free. All aluminium parts have
a high-quality powder coating, as well as the screw connections of
stainless steel.
No corrosion may occur to these components. We advise to clean the
cassette every 6 weeks with a damp cloth.
The awning cloth has a high-quality coating and is therefore suitable
for outside use.
If the awning cloth becomes wet by rain, nothing will happen. The
awning cloth may be rolled up wet, too. However, in this case, we
advise to roll it out again and let it dry when it does not rain anymore.
We advise for the cleaning a solution of laundry detergent and a soft
brush. You can achieve good results in case of stubborn stains also
with a rubber. Never clean by means of a high-pressure device, becau-
se it damages the waterproofing.
Product features of awning coverings
We process exclusively high-quality polyester fabrics in our awnings.
The fibre of the weaving yarn is spun-dyed and therefore also UV-re-
sistant (colour- and light-fast).
A refinement of the surface gives the cloth water-repellent and
dirt-repellent properties. Mould formation is this way also prevented.
Important consumer information:
Awning covers are high-performance products. However, limits to
their perfection are set by environmental protection requirements
and with the current state of technology. Certain phenomena in the
fabric, which sometimes are subject of complain, are possible in spite
www.paramondo.de
7
TDMK-B
230 V
50 Hz
13 U/min
1,06 A
244 W
4 min
50 Nm
< 70 dB