English
300BPE and 300BPES Valves
Thank you for purchasing a Rain Bird
NOTES
300BPE or 300BPES valve for your irrigation
1. Product is shipped configured for globe
system. This rugged valve combines a
installation. For angle installation, use a
robust GFN bonnet with a strong red-brass
closed-end wrench to remove the bottom
body to provide a high quality product at a
plug
H
value price.
Thread plug into the side inlet, which is
opposite the side with the solenoid.
To use this guide, fold out the back page for
2. Replacement solenoids. Do not install
visual reference then turn to the appropriate
black solenoid with top label icon depict-
language. Follow the alphanumeric refer-
ing not for use with 3" BPE/BPES. This
ences for installation, adjustment, trou-
solenoid has been replaced with a more
bleshooting and replacement parts.
durable, green solenoid assembly (part
Specifications can be found on the back of
number B31800). Refer to the
the foldout page.
replacement parts section for assistance.
Installation
Refer to F1.
1. Apply two wraps of Teflon tape as a lubri-
3. Connect one solenoid wire
cant along the full length of the inlet and
controller common wire and the other
outlet pipe threads. Never apply pipe
solenoid wire
thread or pipe dope compound.
wire. Tighten and protect using only
2. Thread main line into globe or angle valve
approved watertight connectors.
inlet
A
and lateral line into valve outlet
4. Before system pressurization, open exter-
B
until hand tight. Reference directional
nal bleed
flow arrows located on the bonnet and
clogging internal ports. Slowly open water
body. Solenoid
C
is always above the
supply to prevent water hammer. After
outlet.
one minute, close external bleed.
Adjustment
Refer to F1.
handle to decrease flow until resis-
1. Using a 1
1
" or adjustable wrench,
2
tance is felt, then counter-clockwise
open the internal bleed feature by
open one turn.
counter-clockwise loosening the sole-
3. Close internal bleed by clockwise
noid adapter
F
one turn.
tightening the solenoid adapter.
2. To optimize performance, use the
4. Refer to the controller operating
flow control handle
G
to adjust the
instruction when programming the
amount of water flowing through the
valve. Counter-clockwise fully open
controller to automatically open and
the flow control. Clockwise turn the
close the valve.
Troubleshooting
Valve will not open
2. If valve only opens with manual
1. Ensure main water supply is on.
bleed, ensure controller is
Ensure upstream valves are open.
programmed to activate the proper
Ensure flow control stem
G
is not
zone valve. Test controller power
closed.
output and service if necessary.
Test solenoid
Troubleshooting (cont.)
a) If controller and solenoid power are
detected, there may be debris in the
solenoid assembly. Remove orange
rubber retainer by twisting and pulling
(avoid stripping the plastic bolt).
upward. Lift off the U-frame and sole-
noid. Use solenoid wrench (part num-
ber B33003) to counter-clockwise
remove the post assembly, being
careful as internal parts could fall out.
b)Remove plunger assembly and clean
debris on parts and solenoid bowl.
Replace plunger ensuring black
surface faces outward. Clockwise
reinstall the post assembly, solenoid,
U-frame and rubber retainer.
c) Persistent problem may be an
obstruction lodged in main pipe.
d)If power is detected at the controller
D
to the
and not the solenoid, inspect and
repair damaged lead wires.
D
to the controller power
Valve will not close
1. Ensure controller is not operating the
valve automatically. Ensure manual
E
to properly vent debris from
internal bleed is off by clockwise
tightening the solenoid adapter.
Ensure manual external bleed is off
by clockwise tightening the bleed
screw.
E
2. Turn off water supply and swap
solenoid
valve; replace solenoid if necessary.
3. Turn off water supply and verify that
the solenoid adapter
F
Replacement Parts
Bonnet Assembly
1 Bleed screw with o-ring
2 Handle, flow control
NP Handle (sold separately)
3 Bolts (10 each)
4 Stem with o-ring, flow control
5 Solenoid seal
6 Bonnet with solenoid seal
7 Bonnet assembly
Solenoid Assembly
8 U-Frame
9 Rubber retainer
10 Coil
11 Base nut (plastic)
C
power input.
12 Tube, welded
damaged; replace if necessary.
Check for debris in solenoid bowl
preventing plunger from creating a
positive seal.
4. Check overall system water-pressure
requirements and ensure that multiple
zone valves are not operating simul-
taneously. Disallowing one zone
valve to close before another opens
can reduce the amount of backpres-
sure needed to close the diaphragm.
5. Turn off water supply and remove
bonnet
I
for possible debris or
damage causing the diaphragm to
stick open.
Leakage
1. Disassemble parts and inspect o-
rings/sealing surfaces for damage.
Check replacement parts exploded
view for missing or replacement
parts.
Accessories or persistent
problems
1. Refer to the appropriate installation
F
and operation manual for specific
troubleshooting procedures
2. Inside the US, please call the Rain
Bird Spec Hotline at (800) 458-3005.
3. Outside the US, please refer to the
C
from an operational
back page for contact information.
4. Always visit us at www.rainbird.com.
F
o-ring is not
Refer to F2.
300BPE
300BPES
204152
204152
13 Plunger/spring assembly
231546
231546
14 O-ring
240134
240134
15 Adapter assembly
231530
231530
16 Solenoid assembly (A)
232063
232063
B Solenoid wrench
208629
208629
Lower Assembly
231306
231306
17 Diaphragm spring
231548
231548
18 Diaphragm assembly
19 Diaphragm assembly
210914
210914
20 Scrapper
627167
627167
21 Plug and o-ring (NPT)
602118
602118
Plug and o-ring (BSP)
602606
602606
O-ring kit (1, 12, 13, 16, 17, 19) 231513
630028
630028
(A) This solenoid assembly supercedes all others.
Accessories
PRS-Dial
TBOS™
DC Latching Solenoid
E
G
I
300BPE
300BPES
629453
629453
202882
202882
231985
231985
B31800
B31800
A
B33003
B33003
321545
321545
231543
231542
231544
231547
231547
F1
231307
231307
231513
A
8
9
10
1
11
16
12
2
13
14
15
3
5
7
6
4
B
17
19
18
C
20
F
D
21
F2
B
H

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

300bpes