Herunterladen Inhalt Inhalt Diese Seite drucken

Disposal And Recycling; Troubleshooting; Maintenance By Customer Service - EINHELL DHG 200 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für DHG 200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Anleitung_DHG_200_SPK7:_
9.3 Maintenance
Maintenance must only be carried out by trained
personnel. Please contact customer service.
9.4 Ordering replacement parts:
Please provide the following information on all orders
for spare parts:
Model/type of the appliance
Article number of the appliance
ID number of the appliance
Spare part number of the required spare part
For our latest prices and information please go to
www.isc-gmbh.info

10. Disposal and recycling

The appliance is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The
appliance and its accessories are made of various
types of material, such as metal and plastic. Defective
components must be disposed of as special waste.
Ask your dealer or your local council.

11. Troubleshooting

If the appliance is operated properly you should
experience no problems with malfunctions or faults. In
the event of any malfunctions or faults, please check
the following before you contact your customer
service.
Fault
The fan motor does not start up, the LED does not
flash
Possible cause
a) Power cut
b) Power cable or power plug damaged
c) Safety temperature limiter switches itself on
Remedy
a) Check the voltage, where necessary wait for the
device to switch on again.
b) Overhaul by an expert
c) Determine the cause of overheating. Air
inlets/outlets should not be covered. Wait at least
10 minutes until the appliance cools down and
switch it on again. If necessary, please contact
customer service.
27.03.2009
14:34 Uhr
Seite 17
Fault
The fan motor does not start up, the LED flashes
Cause
The thermostat is set too low
Remedy
Adjust the thermostat to a higher temperature
Fault
The fan motor is running, the flame is not ignited, the
appliance switches off after a few seconds and the
LED flashes.
Possible cause
a) Too little, incorrect or dirty fuel in the tank
b) Viscosity is too high because of low temperature
levels
Remedy
a) Check the tank contents, then refuel with clean
low-sulphur heating oil or diesel.
b) Use winter diesel
12. Wiring schematics (Fig. 4)

13. Maintenance by customer service

Follow-up maintenance work must only be carried out
by specially trained personnel.
Disconnect the power plug before doing any
cleaning and maintenance work!
Before starting any maintenance work, let the
appliance cool down completely.
Be careful of sharp edges.
Only use original replacement parts, for safety
reasons.
Inadequate maintenance can lead to higher
levels of waste gas, soot, and damage to the
appliance.
We recommend carrying out the following
maintenance work at the indicated intervals:
Fuel tank
The fuel tank must be washed out with clean fuel
every 200 operating hours. Never use water!