Herunterladen Inhalt Inhalt Diese Seite drucken

Poor Cooling, Increase In Interior Temperature - Waeco CoolMatic HDC195 Bedienungsanleitung

Kompressor-kühlschrank
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
HDC195, HDC225
Interior temperature too low at control level "1"
Fault
Compressor runs
constantly
Compressor runs for a
long time

Poor cooling, increase in interior temperature

Fault
Compressor runs for a
long time/continuously
Compressor does not
run often
EN
Possible cause
Thermostat sensor has no contact to
the vaporiser
Short circuit in the thermostat line
Thermostat defective
Large quantities have been frozen in
the freezer compartment
Possible cause
Vaporiser is iced over
Ambient temperature too high
Insufficient ventilation
Condenser is dirty
Fan defective (if installed)
Battery capacity exhausted
Troubleshooting
Remedy
Secure the sensor
Change the thermostat
Remedy
Defrost the vaporiser
Move the refrigerator to
another location
Clean the condenser
Replace the fan
Charge the battery
55

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Coolmatic hdc225

Inhaltsverzeichnis