7.3
Connecting the refrigerator to the power supply
A
NOTICE!
 To avoid voltage drops and loss of performance, keep the
connection cable as short as possible and not be interrupted.
Therefore avoid additional switches, plugs or power strips.
 Disconnect the cooling device and other electric consumers
from the battery before you connect the battery to a quick
charging device.
Overvoltage can damage the electronics of the device.
The refrigerator can be operated with a 12 Volt or 24 Volt DC voltage supply.
For safety reasons, the refrigerator is equipped with an electronic system to
prevent the polarity being reversed. This protects the refrigerator against
reversed polarity when connecting to a battery and against short circuiting.
To protect the battery, the refrigerator switches off automatically if the voltage
is insufficient (see table below).
Cut-off voltage
Cut-in voltage
➤ Determine the required cross section of the cable in relation to the cable
length according to fig. b, page 13.
Key for fig. b, page 13
Coordinate axis
l
A
NOTICE!
Make sure the polarity is correct.
➤ Before starting up the device for the first time, check whether the operat-
ing voltage and the battery voltage match (see type plate).
EN
Installing and connecting the refrigerator
12 V
10.4 V
11.7 V
Meaning
Cable length
Cable cross section
24 V
22.8 V
24.2 V
Unit
m
mm²