Switch
Position Illustration
OFF
DIP 1
ON
ON
DIP 2
OFF
ON
DIP 3
OFF
ON
DIP 4
OFF
The LED displays are on the cover's membrane keyboard.
LED
Display
Lit
Continuous
flashing
Lit
Continuous
flashing
Flashes x 1
Flashes x 2
Flashes x 3
Flashes x 4
Flashes x 5

Setting the DIP switches

Electric or pneumatic safety edge is connected
Optoelectronic safety edge OSE is connected
Pneumatic (pressure switch) safety edge is
connected,
DW testing is active
Electric safety edge is connected
Terminating resistance of the safety edge =
1.2 kOhm
Terminating resistance of the safety edge =
8.2 kOhm
Closing in automatic mode (only with safety strip)
Closing in dead-man mode

LED displays

Normal mode
Setting mode
SKS connected, or faulty
LS connected
Slack rope switch or safety circuit is open
Running time exceeded (running time is 90 s)
Negative DW testing
Pre-limit switch set too high (testing time is 5 s)
No redundant safety features