Manufacturer: Automatismi Benincà SpA.
Address: Via Capitello, 45 - 36066 Sandrigo (VI) - Italia
Herewith declares that: battery charge controller for photovoltaic panel CP.BULL8 OMSUNNY.
complies with the following relevant provisions:
EMC guidelines: 89/336/CCE, 93/68/CEE
Low voltage guidelines: 73/23/CEE, 93/68/CEE
Benincà Luigi, Legal responsible.
Sandrigo, 08/07/2010.
WARNINGS
This manual has been especially written to be use by qualified
fitters.
None of the information provide in this manual can be considered
as being of interest for the end users.
Preserve this manual for future needs.
The technician has to furnish all the information related to the step
by step function, the manual and the emergency function of the
operator, and to deliver the manual to the final user.
Foresee on the supply net an onnipolar switch or selec-
tor with distance of the contacts equal or superior to 3
mms.
Verify that of the electrical system there is an awry differential
interrupter and overcurrent protection.
Some typologies of installation require the connection of the
shutter to be link at a conductive mass of the ground according
to the regulations in force.
The electrical installation and the operating logic must comply
with the regulations in force.
The leads fed with different voltages must be physically separate,

TEChNICAL DATA

Type of battery
Emergency power supply
Type of photovoltaic panel
Power supply output)
Protection level
Operating temperature
Radio receiver
No. of codes storable in memory
8
EC declaration of confirmity
or they must be suitably insulated with additional insulation of
at least 1 mm.
The leads must be secured with an additional fixture near the
terminals.
During installation, maintenance and repair, interrupt the power
supply before opening the lid to access the electrical parts
Check all the connections again before switching on the po-
wer.
The unused N.C. inputs must be bridged.
The descriptions and the present illustrations in this manual are
not binding. Leaving the essential characteristics of the product
unchanged, the manufacturer reserves himself the right to bring
any change of technical, constructive or commercial character
without undertaking himself to update the present publication.
24Vdc 6.5 ÷ 50 Ah, Pb-Lead
230/110>> 24 Vac 45 VA minimum Transformer
Vmp: 15 ÷ 40V (load voltage)
Wp: 15 ÷80 W (max. power)
24VDC
IP 55
-20°C / +70°C
433.92 MHz, built-in and configurable (rolling-code or fixed+rolling-code)
512