THERMO TECHNICAL CHARACTERISTICS
Tank capacity
Efficiency
Max. power output
Available power
Fuel consumption (min./max.)
*
Heating capacity
Weight (including packaging)
Diameter smoke duct (male)
Diameter air intake duct (male)
*
The heatable room dimensions are calculated on the basis of pel-
lets with an lhv of at least 4300 kcal/kg and home insulation in com-
pliance with Italian law 10/91, and subsequent changes together with
an expected heat output of 33 Kcal/m³ per hour.

ELECTRICAL DIAGRAM

RS485/AUX
M
N
SOS
AUX
F
R
RS485 SERVICE
LITHIUM
+
CR2032
A
D
SMOKE
EXPULSION MOTOR
F
RIGHT-HAND
TM 150 °C
VENTILATION
LEFT-HAND
VENTILATION
M COCHLEA
AUX/RS485 PORT
(connected via optional serial port cable code 640560)
This is a clean, potential free contact, useful for connecting a
telephone combiner or other control devices via an optional
cable.
FEATURES
15
kg
90,1
%
8
kW
8 /30
hours
0,5 / 1,9
kg/h
210
157
kg
80
mm
50
mm
G
L
H
FLOW
SENSOR
RPM SMOKE
IN
J
RESERVE
SENSOR
Room
(optional)
temperature
PROBE
(optional)
R
P
AUXILIARY
B
C
VENTILATION
RES IGNITION
MAINS 230
VAC
50 Hz +/-10%
E
ELECTRICAL CHARACTERISTICS
Power supply
Average power consumed
Power consumed upon
ignition
Remote control frequency
(as standard)
Protection on electronic
*
board
N.B.
1) bear in mind that external devices may cause interference.
2) caution: live parts. Servicing and/or inspections must be
carried out by qualified staff.

SAFETY DEVICES

• THERMO COUPLING: located on the smoke
exhaust, detects the temperature. On the basis of the
parameters set, check the ignition, working and turn-
off phases.
• AIR FLOW SENSOR: Positioned in the suction
channel, this intervenes when the fuel air flow is
incorrect, with consequent depression problems in
the smoke circuit.
• SAFETY THERMOSTAT (150 °C): Intervenes
when the temperature within the insert is too high.
Blocks pellet loading causing the insert to turn off.
• ROOM TEMP. DETECTION PROBE: located
on the remote control. Alternatively it can be connec-
ted up to the electronic board inside the insert.

BACKUP BATTERY

A backup battery is found on the control board (3-Volt
CR 2032 battery). Its malfunction is indicated with the
following messages: (not considered a defect but due
to normal wear-and-tear): "Battery check". For more
detailed information, please contact the DEALER who
has performed the first 1st ignition.
PELLET LOADING
A convenient front drawer allows you to load the pel-
lets in complete comfort, without having to remove
the hearth from its housing, and therefore in absolute
safety and in compliance with standards EN 14785.
21
230V
10% 50 Hz
ac +/-
120
W
400
W
Radio waves 2.4
GHz
Fuse 2°AT, 250 V
AC 5x20

Werbung