Herunterladen Inhalt Inhalt Diese Seite drucken

Cola TERMO-FOCUS Serie Installations-, Bedienungs- Und Wartungsanleitung Seite 51

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Hydraulic diagram - heating pellet stove ref.
Heating pellet stove
Pellet heating
chamber – 2010
Pt=10-14 kW
Int. volume 18.5 lt.
KEY
Drain cock
Pressure sensor / Pressure gauge
Circulating pump
Membrane pressure vessel
Shutoff valve / Cock
Non-return valve
Emergency
2.10
Suitable fire-prevention devices should be arranged for any eventuality.
In case of a fire, proceed as follows:
- Immediately disconnect the plug.
- Extinguish the fire using fire-extinguishers (powder).
- Call the fire department immediately.
- Do not use jets of waters to extinguish the fire.
COLA 10-14kW-06-2010
Thermostat
T > 85° C
Circuit / heating chamber air ven
Safety valve P max 3 bar
Safety sensor T > 85° C
Water temperature sensor
Circuit pressure sensor
Valves to be included in system during
installation – not supplied with the unit
51
Heating DELIVERY
male 3/4"
OVERPRESSURE WATER
DISCHARGE F1/2"
Heating RETURN
male
3/4"
Water supply F1/2"
Pmax 2 bar
Arrangement
PLUMBING CONNECTIONS on back of stove
TERMO-FOCUS M

Werbung