AC (automatic range selection)
Measuring range
2 A
20 A
200A
600A
Frequency response: 40-400 Hz
Maximum input current: 600 A AC
The value is displayed and retained, this measurement is only carried out once.
After the measurement, keep the "SEL" button pressed, to change to the normal measurement
mode, by again pressing, returns to the inrush measurement.
DC voltage (automatic range selection)
Measuring range
200 mV
2 V
20 V
200 V
600 V
Input impedance: 10 M
Maximum input voltage. 600V DC or 600V AC RMS.
AC voltage (automatic range selection)
Measuring range
2 V
20 V
200 V
600 V
Input impedance: 10 M
Frequency response: 40-400 Hz
Maximum input voltage. 600 V DC or 600 V AC RMS.
®
Testboy
TV 215N
Information for the measurement
Resolution
0.01 A
0.1 A
0,1 A
1 A
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
0.1 V
Tolerance
± 3.5 % + 10 digit
± 1.5 % + 10 digit
± 2,5 % + 10 digit
± 3.0 % + 10 digit
Tolerance
± (0.8 % + 3 digits)
± (1.0 % + 5 digits)
± (1.0 % + 5 digits)
Tolerance
± (1.0 % + 5 digits)
± (1.0 % + 5 digits)
± (1.2 % + 10 digits)
23