Herunterladen Inhalt Inhalt Diese Seite drucken

tau ARM200 Bedienungs- Und Wartungsanleitung Seite 14

Vorschau ausblenden Andere Handbücher für ARM200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
ARM270I
A (mm)
90
150
90
155
90
160 ÷ 165
90
170
90
175 ÷ 180
90
185
90
190
90
195
90
200 ÷ 205
90
210
90
215
90
220 ÷ 225
100
175
100
180
100
185
100
190
100
195
100
200
100
205
100
210
100
215
100
220
100
225
110
210
110
215
110
220
110
225
When measurement "C" is greater/smaller than 20 mm, increase/
diminish measurement "B" by the difference (e.g.: if C= 25mm, in-
crease "B" by 5mm), making sure that it does not exceed the limits
shown in the table.
Note: to work correctly, the angle formed by the ac-
tuator and the gate (Y° fig. 4) must be > 3° (ARM225
- ARM250) and > 4° (ARM270) both with the gate
completely closed and completely open.
Note: for a quick opening and optimum closed-
holding position (gates with an electrical lock), use
the maximum dimension "B" shown in the tables.
If the pillar dimensions or the hinge position do not allow the in-
stallation of the actuator, a niche on the pillar, as shown in Fig. 5,
should be created in order to maintain the A dimension as deter-
mined. The niche should be dimensioned in such a way to enable
easy installation, actuator rotation and operation of the release
device. The mounting brackets are designed to enable small ad-
justments in both directions (fig.5A), it is possible to use the two
multipoint brackets overlapped (pict. 5B: in this case the only holes
to be used are the 3 highlighted, according to the direction of the
leaf movement). In any case, always refer to the measurements
shown in the table.
Please keep to the values given in the table and oil the gate's
hinges.
1_ Fix the rear bracket in the position determined before. In the
event of iron pillar carefully weld directly the bracket or use n°4
suitable screws (fig.6). In the event of brick pillar (fig.7), use n°4
suitable bolts (after you have assembled it, fig.7A).
During the fastening operations, check if the bracket is
perfectly horizontal by means of a level.
WARNING - In case of large gate leaves and /or
closed design leaves other than the installation of
an electro lock it is suggested to strengthen the
fastening of the back bracket (weld the steel parts
instead of using screws to assemble the bracket,
use steel anchors instead of the dowels, weld the
bracket onto the pillar, etc.).
2_ Set the operator for manual operation (see paragraph MANU-
AL RELEASE).
3_ Completely extend the rod till it reaches the limit stop (1 fig.8).
4_ Lock the operator again (see paragraph RESTORING NOR-
MAL OPERATION).
5_ Turn the rod clockwise half a revolution (2 fig.8).
6_ Assemble the front bracket as shown in fig.9. Fasten the screw
14
B (mm)
C (mm)
170 ÷ 345
20 mm
170 ÷ 340
20 mm
170 ÷ 335
20 mm
170 ÷ 330
20 mm
170 ÷ 325
20 mm
170 ÷ 320
20 mm
170 ÷ 315
20 mm
170 ÷ 310
20 mm
170 ÷ 305
20 mm
170 ÷ 300
20 mm
170 ÷ 295
20 mm
170 ÷ 290
20 mm
170 ÷ 170
20 mm
170 ÷ 220
20 mm
170 ÷ 280
20 mm
170 ÷ 285
20 mm
170 ÷ 280
20 mm
170 ÷ 275
20 mm
170 ÷ 270
20 mm
170 ÷ 265
20 mm
170 ÷ 260
20 mm
170 ÷ 255
20 mm
170 ÷ 250
20 mm
170 ÷ 175
20 mm
170 ÷ 190
20 mm
170 ÷ 210
20 mm
170 ÷ 225
20 mm
ARM200 Series
using the special nut and insert the self-lubricating bushing into
the bracket as shown on Fig. 9.
7_ After removing the terminal board cover, anchor the actuator
to the rear bracket using the screw and nut supplied (see 1
fig.10);
ATTENTION: The actuator can be moved by hand only if it
is installed on the gate and in released position (see para-
graph MANUAL RELEASE).
ATTENTION: carefully verify that, when gate is
closed, the actuator's rear do not touch the bracket
(see fig. 10). If so adjust the setting accordingly.
8_ Check measurement "L" according to the table (fig.4).
9_ rest the bracket that has just been fixed, onto the wing of the
completely closed gate and mark the fixing points (make sure it
is level, see fig. 11).
Before going on to the next phase please carry out the following
test:
10_ Release the actuator (see paragraph MANUAL RELEASE)
and manually check if the gate can completely open without
hindrances and stop at the mechanical travel stoppers (floor-
mounted mechanical stoppers) as well as if the leaf moves
regularly without any friction.
11_ Carry out the necessary corrective measures and repeat
from point 10. Manually open the gate to the maximum re-
quired angle;
12_ Tighten the arm until the front bracket finds itself over the
position just marked on the gate.
If the small bracket does cover the position marked it means instal-
lation has been done correctly.
This method can be used to establish where the small bracket will
have to be welded for each opening angle (X°) required provided
it is possible (parameters A and B and the actuator's useful travel
permitting).
13_ fasten the gate mounting bracket in the position indicated
(fig.12), referring to the dimensions shown in fig. 13 and en-
suring the planarity of the assembly.
Note: if the gate structure does not allow a fix brack-
et fastening it is necessary to create a sturdy sup-
porting base in the gate structure.
Note: for complete safety, the mechanical stops with
rubber cap (floor stops) must be fitted in opening
and closing of the gate (7 fig. 3), in order that they
intervene just before the mechanical piston stops.
WIRING THE ACTUATOR
A terminal board is fitted in the lower part of the actuator for the
connection of the motor, of any limit switch and for the earthing of
the actuator. (figg.14-15).
Connect the motor and the earthing with reference to fig.14-15 and
to the table.
ARM200 - 230V AC
POS. COLOR
1
Blue
2
Brown
3
Black
T
Yellow / Green
Connect up the condenser in parallel to the 2 phases of the motor
(terminals 2 and 3). Warning! Do not short-circuit the two wires as
this may cause discharges because of the current remaining in the
wires. Use control units with torque limiting device only.
ARM200BENC - 18V DC
POS. COLOR
1
Brown
2
Blue
3
White
4
Black
5
Red
Only use control units fitted with an electric clutch.
The distance between the control unit and the motor must not ex-
ceed 10 – 12 m.
TAU srl recommends its composite cable, Code M-03000010CO;
Place the control unit (external versions) in the im-
mediate vicinity of the
Be careful not to run cables for auxiliary devices in-
side raceways housing other cables supplying pow-
er to large loads or lights with electronic
DESCRIPTION
Common cable
Phase 1
Phase 2
Earthing
DESCRIPTION
Encoder positive
Encoder negative
Encoder signal
Motor negative
Motor positive
motors.
starters.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Arm200-serieArm270Arm250Arm225

Inhaltsverzeichnis