Herunterladen Inhalt Inhalt Diese Seite drucken

LiftMaster AGO250L Anleitungen Seite 10

Drehtorantrieb – gelenkarm
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CHECK ON OPERATION
Activate the function "Automatic close" on the control unit. If
the gate opens automatically after the preset time, exchange
the brown and black leads.
LIMIT SWITCH
1. Most control units have a time function. This should always
be set 3 - 5 seconds more than the time actually required.
The preliminary setting should be made for more than this
to allow a safety margin. After the necessary adjustments
to the system have been made, the time can be set more
accurately. NB: The drive works more slowly under
windy conditions.
2. The internal limit switch of the AGO turns the drive off
when the preset point is reached. Remove the cover of the
drive unit, and turn the cam until the desired end point has
been reached. Check which cam has which function (e.g.
top cam opens gate).
Switch the drive on, let it run until the desired point is
reached and interrupt the current with the aid of the main
switch. Now turn the limit-switch dial to the microswitch
trigger point. Tighten the cam with an Allan key until it
cannot be moved further. Repeat this procedure on all
limit-switch dials.
SAFETY MEASURES
The wing gate opener should always be operated in
conjunction with flashing lights, contact strips and
photoelectric barriers for added safety. In any case, take care
to comply with the relevant standards and regulations.
FINAL REMARKS
Arrange the handover of the wing gate opener with your
customer Make sure that persons will operate the gate are
familiar with its functions and can operate them without
problems. Have your customer practice operating the gate
until he is fully acquainted with all the following:
• Main switch.
• Rules of operation (e.g. do not drive through while the gate
is still opening).
• Additional safety features (photoelectric barrier, contact
strip, flashing lights, etc.).
• Switch to manual operation in case of power failure.
• Provide the customer with a full set of instructions. Inform
him to keep them in a safe place and read them when
possible.
• Reference a checklist, so that you have a record of which
functions have been explained and of any points not dealt
with.
Fig. 10 shows the complete installation.
709153-GB
ACCESSORIES
(1) Model FLA230-2
(2) Model 100263
(3) Model 100027
Model 100041
(4) Model 760E
(5) Model 600046
(6) Model 600053
(7) Model 600060
(8) Model 600152
(9) Model 600077
(10) Model 600145
(11) Model 600138
(12) Model 600176
(13) Model 600169
(14) Model 600008
(15) Model 600015
© Chamberlain GmbH, 2000
10
Flashing Light
Infrared barrier
1-Function Keyswitch,
surface mount
(Flush mount - 100010)
2-Function Keyswitch,
surface mount
(Flush mount - 100034)
Key switch
2.5 Safety Edge Set (Small)
20m Bulk Pack Safety Edge
Profile (Small)
Assembly Pack Safety Edge
(Small)
Assembly Pack Safety Edge
(Medium/Large)
Bulk pack (not shown)
20m Bulk Pack Safety Edge
Profile (Large) (not shown)
20m Bulk Pack Safety Edge
Profile (Medium) (not shown)
1m Safety Edge Profile (Large)
(not shown)
1m Safety Edge Profile (Medium)
(not shown)
IR Sensor Stand - 530mm
Key Switch Stand - 1100mm

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ago250r

Inhaltsverzeichnis