8. Approvals
CE/EN
The SR 200 with polycarbonate visor is approved in ac-
cordance with EN 136:1998, class 3.
The plastic visor has been tested against EN 166:1995,
class B.
The SR 200 with glass visor is approved in accordance
with EN 136:1998, class 2.
The SR 200 in combination with fan unit SR 500/SR 700 is
approved in accordance with EN 12942:1998, class TM3.
The SR 200 in combination with compressed air at-
tachment SR 307 is approved in accordance with EN
14594:2005.
The SR 200 in combination with fan unit SR 500 EX is
approved in accordance with EN 12942:1998, class TM3,
ATEX Directive 94/9/EC and the IECEx scheme.
Australian StandardsMark
The full face mask SR 200 is tested and certified to
comply to AS/NZS 1716:2012. The StandardsMark is
issued under licence by SAI Global Pty Limited LIC No.
766 (ACN 108 716 669) ("SAI Global").
ATEX-codes:
II 2 G Ex ib IIB T3 Gb (SR 200 with glass visor).
II 2 G Ex ib IIA T3 Gb (SR 200 with PC visor).
II 2 D Ex ib lllC 21 T195°C Db (SR 200 with PC/
glass visor).
Key to ATEX markings:
Explosion protection mark.
II
Equipment group (explosive atmospheres
other than mines with fire damp).
2 G
Equipment category (2 = High level of
protection for Zone 1, G = Gas).
2 D
Equipment category (2 = High level of
protection for Zone 21, D = Dust).
Ex
Explosion protected.
Type of protection (Intrinsic safety).
ib
IIA
Gas group (Propane).
Gas group (Ethylene).
IIB
IIIC
Dust material group (zone with conductive
dust).
T3
Temperature class, gas (maximum surface
temperature +200°C).
T195°C Temperature class, dust (maximum surface
temperature +195°C).
Equipment Protection Level, gas (high
Gb
protection).
Equipment Protection Level, dust (high
Db
protection).
32
IECEx-codes:
Ex ib IIB T3 Gb (SR 200 with glass visor).
Ex ib IIA T3 Gb (SR 200 with PC visor).
Ex ib IIIC T195°C Db (SR 200 with PC/glass visor).
Key to IECEx markings:
Ex
Explosion protected.
ib
Type of protection (Intrinsic safety).
IIA
Gas group (Propane).
Gas group (Ethylene).
IIB
IIIC
Dust material group (zone with conductive dust).
T3
Temperature class, gas (maximum surface
temperature +200°C).
T195°C Temperature class, dust (maximum surface
temperature +195°C).
Gb
Equipment Protection Level, gas (high
protection).
Db
Equipment Protection Level, dust (high
protection).
Type approval in accordance with PPE Directive
89/686/EEC has been issued by Notified Body No. 0194.
For address, see back cover.
Type approvals in accordance with ATEX Directive 94/9/
EC and IECEx Scheme have been issued by Notified
Body No. 0470. NEMKO AS, Gaustadalléen 30, N-0314
Oslo, Norway.