4.0 Safety instructions

-
-
-
-
-
-
-
-
-
-
-
-
-

5.0 Placing in service

-
-
-
-
-
-
-
-
8
Aquamax 2000_Standart_o_Garantie.p65
GB
Operating instructions
For your own safety, please contact an electrical specialist in case of
questions and problems!
Before reaching in the water, always unplug all power cords of devices
in the water.
Plug in the pump only to a power receptacle with ground contact. This
type of outlet must have been set up according to the respective national
directives (VDE, EN... IEC etc.) Insure that the PE conductor extends all the
way to the pump.
Never use installations, adapters, extension cords or connecting cords without
ground contact!
Insure that the pump is supplied via a residual current device (Fl or RCD)
with a measured residual current of not more than 30mA.
Electrical installations on garden ponds must correspond to the internatio-
nal and national installation directives.
Only operate the pump if no one is in the water!
Do not carry or pull the pump by the connecting cord!
Keep the power plug and all connecting parts dry!
The pump may not be operated if the cable or the housing are defective!
The connecting cord of the pump cannot be replaced. If the cable is
damaged, the pump must be disposed of.
Never displace any substance other than water!
Caution! The built in temperature monitor automatically turns off the
pump in the case of overload (a blocked rotor for example). After the motor
cools down the pump will restart automatically. Accident hazard!
Read and familiarize yourself with the safety instructions (section 4.0)
before placing in service!
Compare the line voltage (V) and frequency (HZ ) of your electrical
circuit with data on the model plate. These data must agree.
Make the necessary hose connections (if required), or install a fountain
attachment. After the installation insure that there are no air bubbles in the
hose system (lay hose lines on an incline).
Install the pump horizontally on a fixed support at least 20 cm under the
water surface. Comply with the maximum permitted immersion depth
(see the information on the model plate).
Do not place the pump directly in the pond floor mud; place the pump
on a raised surface.
Lay the connecting line in a protected manner to exclude the possibility of
damage.
Connect the pump to the electrical circuit.
Adjus t the pump capacity , if required, by turning the regulator as
appropriate.