6.0 Maintenance/cleaning
-
-
7.0 Winter care
-
-
-
-
-
8.0 Trouble shooting
Caution: Follow the safety instructions (section 4.0).
M alfunction
Pump does not turn on
Pump does not displace
water
Insufficient water dis-
placement
The pump turns off after
running for a short time
Aquamax 2000_Standart_o_Garantie.p65
GB
Operating instructions
Never operate the pump without the filter basket. The filter basket protects
the pump from coarse dirt that can lead to blockage of the pump.
Never operate the pump without water (dry run). The pump bearings will
be destroyed!
Follow the safety instructions (section 4.0).
Clean the filter housing monthly, or if the pump capacity is reduced, by using
a soft brush under running water or use the OASE special cleaner (order
number 52969). If the pump unit is blocked by dirt, dismantle the housing (See
figure. page 11).
Take the pump out of the water.
Thoroughly clean the pump (see section 6.0)
Check the pump for damage.
Store the pump in frost-free conditions, in a container with water if possible.
Caution: Never immerse the connecting plug!
Cause
· There is no power
· Filter housing/filter sponge is
blocked
· Rotor is blocked
· Filter housing/filter sponge is
blocked
· Excessive loss in the supply
lines
· W ater is very dirty
· The water temperature is too
high
9
Rem edy
· Check the electrical circuit
· Clean filter housing (section 6.0)
· Clean pump (section 6.0)
· Clean filter housing (section 6.0)
· Reduce hose lengths to the
minimum required, do not use
unnecessary connecting part
· Clean pump (section 6.0)
· Insure that the water temperature
does not exceed +35°C