Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions; Placing In Service - Oase AquaMAX 3500 Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für AquaMAX 3500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.0 Safety instructions

-
-
-
-
-
-
-
-
-
-
-
-
-

5.0 Placing in service

-
-
-
-
-
-
-
-
Aquamax 3500 Export NEU.p65
GB
Operating instructions
For your own safety, please contact an electrical specialist in case of
questions and problems!
Before reaching in the water, always unplug all power cords of devices
in the water.
Plug in the pump only to a power receptacle with ground contact. This
type of outlet must have been set up according to the respective national
directives (VDE, EN... IEC etc.) Insure that the PE conductor extends all the
way to the pump.
Never use installations, adapters, extension cords or connecting cords without
ground contact!
Insure that the pump is supplied via a residual current device (Fl or RCD)
with a measured residual current of not more than 30mA.
Electrical installations on garden ponds must correspond to the internatio-
nal and national installation directives.
Only operate the pump if no one is in the water!
Do not carry or pull the pump by the connecting cord!
Keep the power plug and all connecting parts dry!
The pump may not be operated if the cable or the housing are defective!
If the power cord of the pump is damaged then it must be replaced by the
manufacturer or his customer service or by a similarly qualified
person, to avoid hazard.
Never displace any liquids other than water!
Caution! The built in temperature monitor automatically turns off the
pump in the case of overload (a blocked rotor for example). After the motor
cools down the pump will restart automatically. Accident hazard!
Read and familiarize yourself with the safety instructions (section 4.0)
before placing in service!
Compare the line voltage (V) and frequency (HZ) of your electrical
circuit with the data on the model plate. These data must agree.
Fasten a hauling rope to the pump. With this rope you can pull the pump out
of the water as needed.
Make the necessary hose connections (if required), or install a fountain
attachment. After the installation, insure that there are no air bubbles in the
hose system (lay hose lines on an incline).
Install the pump horizontally on a fixed support at least 20 cm under the
water surface. Comply with the maximum permitted immersion depth
(see the information on the model plate).
Do not place the pump directly in the pond floor mud; place the pump
on a raised surface.
Lay the power cord in a protected manner to exclude the possibility of damage.
Connect the pump to the electrical circuit.
9
GB
14.02.2003, 10:50
9

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Aquamax 10000Aquamax 5500Aquamax 15000

Inhaltsverzeichnis