INSTALLATION
CLEARANCES
WARNING
Choose the place of installation in strict
observance of local regulations regar-
ding safety in the workplace.
IMPORTANT: for correct, safe use of the
equipment, users must ensure a lighting
level of at least 300 lux in the place of
use.
ATTENTION
If the machine is to be installed outdoors,
it must be properly protected from
adverse weather by a roof.
ATTENTION
The floor must be able to withstand a
load equal to the sum of the weight of
the equipment itself and the maximum
payload, bearing in mind the support
surface area and eventual anchor fix-
tures used.
Place the tyre changer in the designated
work position observing the minimum
clearances shown in figure 4.
Ambient conditions in the place of
operation
- Relative humidity from 30% to 95%
without condensation.
- Temperature range from 0∞C to 50∞C.
ATTENTION
The machine must not be operated in
potentially explosive atmosphere.
26
ELECTRICAL AND
PNEUMATIC HOOK-UPS
WARNING
All operations required for the electri-
cal hook-up of the machine must be
carried out exclusively by a qualified
electrician.
- The electrical supply must be suitably
sized in relation to:
• absorbed power specifications indica-
ted on the machine dataplate.
• the distance between the machine and
the power supply hook-up point, so that
voltage drops under full load do not
exceed 4% (10% in the case of start-up)
below the rated voltage specified on
the dataplate.
- The user must equip the machine with
the following:
• a dedicated power plug in compliance
with the relevant electrical safety
standards;
• a type A and B suitable circuit-breaker
(residual current set to 30 mA) on the
mains connection;
WARNING: only a type A and B differential
security breaker of the specified kind
will be tripped correctly in response to
all the failure currents which may occur
on the machine.
• power line fuses in accordance with
specifications in the main wiring dia-
gram of this manual;
• a suitable earthing system installed on
the workshop mains line.
- To prevent unauthorised use of the ma-
chine, always disconnect the mains plug
when the machine is not used (switched
off) for extended periods of time.
- If the machine is connected directly to
the power supply by means of the main
electrical panel and without the use of a
plug, install a key-operated switch or sui-
table lock-out device to restrict machine
use exclusively to qualified personnel.
For correct operation of the machine the