Herunterladen Inhalt Inhalt Diese Seite drucken

Sony AIT Autoloader LIB-D81 Kurzanleitung Seite 20

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 43
When problems occur
When problems occur, the ERROR/WARNING or
CLEANING LED lights or flashes, and one of the
following codes appears on the message display.
ERROR
WARNING
CLEANING
LED
Lit/Flashing
ERROR/
WARNING
Flashing (orange)
ERROR/
WARNING
Lit (orange)
20
Explanation of the Display
Code
Description
[L ] and [X X]
appear alternately
Loader error.
on the message
display.
[d ] and [X X]
appear alternately
AIT drive error.
on the message
display.
[C ] and [X X]
appear alternately
Data cartridge error.
on the message
display.
Cartridge not completely
0 1
inserted.
Cleaning cartridge not
0 3
inserted at the beginning
of cleaning.
A data cartridge was
0 4
inserted in slot CL/8 at the
beginning of cleaning.
The DOOR button is
pressed, when the front
0 5
door is locked by an
application.
Internal temperature
0 6
abnormally high.
Parts replacement
0 7
needed.
Too many cartridges in the
loader. (There are
0 8
cartridges in all the slots
and the AIT drive.)
The internal temperature
0 9
of the device is too low to
guarantee operation.
Cleaning cartridge tape
1 0
spent.
1 1
Cleaning failed.
Remedy
Restart the system and verify if the
error message disappears. If it occurs
again, note the error code and contact
customer service for repair. When [L]
and [XX] appear, refer to "Error Code
List" in the Appendix of the Operating
Instructions (PDF).
Replace the data cartridge after
cleaning the AIT drive. If the same
problem occurs after doing so, contact
customer service for repair.
Open the front door and reinsert
cartridges as necessary.
Insert the cleaning cartridge in
slot CL/8.
Insert the cleaning cartridge in
slot CL/8.
Do not attempt to open the front door
manually.
Make sure that the operating
environment is within the allowed
temperature limits (5 to 40 °C) and
verify that AIT autoloader fan is
operating normally.
For replacement parts, contact
customer service.
Eject one or more cartridges from the
AIT autoloader.
Make sure that the operating
environment is within the allowed
temperature limits (5 to 40 °C).
A spent cleaning cartridge is set.
Replace the spent cleaning cartridge
with a new one.
Cleaning failed. Repeat the cleaning
procedure.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis