Start-up
Space required according to the
appliance dimensions
C
B
A
A:
480 mm
C:
100 mm
E:
1050 mm
G:
50 mm
I:
890 mm
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installation
space must have a minimum size of 4,5 m³.
– The appliance must only be placed on a
level and firm surface. The surface must be
strong enough to support the appliance's
weight when fully laden.
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
G
D
B: 1285 mm
D:
526 mm
F:
100 mm
H:
150 °
F
G
H
I
– Unsuitable locations are ones with direct
sunlight or which are directly next to an ov-
en, hob or radiator.
– The following minimum distances must be
maintained:
– from electrical hobs
– from oil and coal burning stoves 100 cm
– from other cooling appliances
– from washing machines/
dishwashers
– If you would like to reduce these distances,
you can fit an insulation plate between the
appliances.
– If underfloor heating is installed at the set-
up location, place the cooling appliance on
an insulation plate made from solid mate-
rial.
E
20 cm
20 cm