Start-up

Heating mode is possible with or without water
content depending on the operating mode.

Hot water mode

This operating mode can only be used if the boiler has
been filled.
Appliances with electrical heating elements
Select diesel or electric mode using the power selector switch.
Illumination of the yellow LED (o) at the power selector switch
indicates that the appliance is operating with 230 V .
Mixed mode (diesel and electric mode) is not possible
in hot water mode. With this setting, the appliance au-
tomatically selects electric mode with the preset operating
level of 900 W or 1800 W. If the 230 V
disconnected or fails, the heater automatically switches
over to diesel mode.
Move the rotary switch on the control panel to position (c –
hot water mode) 40 °C or 60 °C. The green (b) and yellow (g)
LEDs light up.
After reaching the set water temperature (40 °C or 60 °C),
the heater will switch off and the yellow LED (g) will be
extinguished.

Heating mode

Appliances with electrical heating elements
Select diesel, electric or mixed mode using the power
selector switch. Illumination of the yellow LED (o) at the
power selector switch indicates that the appliance is
operating with 230 V .
– Heating with water temperature monitoring
Move rotary switch on control panel to "On" position (e).
Set the control knob (a) to the desired thermostat setting (1 – 5).
The green LED (b) for operation is lit and simultaneously in-
dicates the position of the selected room temperature. The
yellow LED (g) indicates the water's heat-up phase.
The appliance automatically selects the required operating level
according to the temperature difference between the setting
power supply is
on the control panel and the current room temperature. After
the room temperature set on the control panel is reached, the
heater switches back to the lowest setting and heats the water
content to 60 °C. After the water temperature is reached, the
heater switches itself off and the yellow LED (g) goes out.
– Heating without water temperature monitoring
Move rotary switch on control panel to "On" position (d).
Set the control knob (a) to the desired thermostat setting (1 – 5).
The green LED (b) for operation is lit and simultaneously in-
dicates the position of the selected room temperature. The
yellow LED (g – water heat-up phase) will be lit only when the
water temperature is below 5 °C!