Herunterladen Inhalt Inhalt Diese Seite drucken

Starting And Operating Instructions - ABS J Betriebsanleitung

Submersible drainage pump
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5

Starting and operating instructions

Example of rating plate
Year of manufacture
Type designation
Main power
Voltage/method of
start
Rated current
Manufacturer, address
Applications
These starting and operating instructions are applicable to electric submersible pumps
specified on the cover. The pumps are intended for pumping water that may contain abra-
sive particles.
c
DANGER! The pump must not be used in an explosive or flammable
environments or for pumping flammable liquids.
The pumps conform to the EU machine directive. See rating plate.
The manufacturer guarantees that a new pump will not emit airborne noise in excess of 70
dB(A) during normal operation, when either fully or partially submerged.
m
CAUTION!
The pump must not be run if it has been partially dismantled.
c
CAUTION! Earth leakage detector (RCD Residual-current device) is
recommended to be used when a person come in contact with either
the pump or the pumped media.
Special regulations apply for permanent installation of pumps in swimming
pools.
Product description
Limitations
Immersion depth: up to 20 m/65 ft (J 5: 8 m/26 ft). Liquid temperature: up to 40°C (105°F).
Motor
Single-phase AC motor or 3-phase squirrel-cage induction motor for 50 or 60 Hz.
Level control
Some pumps can be equipped with float switch for automatic level control.
Motor protection
Single-phase pumps have a built in start- and run-capacitor. For built in motor protection,
the thermal contacts in the motor are fitted to disconnect the power at high temperature.
The thermal contacts can as alternative be connected to an external motor protection.
Electric cable
HO7RN-F or equivalent cable. If the cable is longer than 20 m, the voltage drop must be
taken into account. Note that the pumps can be supplied with different cables and for dif-
ferent connection methods.
Handling
The pump can be transported and stored either vertically or horizontally. Make sure that it
is secured and cannot roll.
m
CAUTION! The pump must always rest on a firm surface so that it will
not overturn. This applies to all handling, transport, testing and in-
stallation.
m
CAUTION! Always lift the pump by the lifting handle - never by the
motor cable or hose.
NOTE! Always protect the cable end so that no moisture will penetrate into the
cable. Water could otherwise seep into the terminal compartment or into the mo-
tor through the cable.
If the pump is stored for a long period of time, protect it against dirt and heat.
After a longer period of storage, the pump must be inspected and the impeller must be
rotated by hand before the pump is taken into operation. Check the seals and cable entry
particularly carefully.
Installation
Safety measures
In order to reduce the risk of accidents during service and installation work, take extreme
care and bear in mind the risk of electrical accidents.
m
CAUTION! The lifting tackle must always be designed to suit the pump
weight. See under the heading "Product description".
Pump installation
Arrange the cable run so that the cables will not be kinked or nipped.
Connect the cable. Connect the delivery piping. Hoses, pipes and valves must be selected
to suit the pump delivery head.
Place the pump on a firm surface which will prevent it from overturning or burrowing down.
The pump can also be suspended by the lifting handle slightly above the bottom.
4
Degree of protection
Speed of rotation
Serial number
Rated power
Frequency
Weight
Max. flow
Delivery head
The manufacturer reserves the right to change the design and specifications.
Electrical connections
The pump must be connected to terminals or starting equipment installed at a level at which
it cannot be flooded.
c
CAUTION! All electrical equipment must always be earthed (ground-
ed). This applies both to the pump and to any monitoring equipment.
c
CAUTION! The electrical installation must conform to national and lo-
cal regulations.
Check that the mains voltage, frequency, starting equipment and method of starting agree
with the particulars stamped on the motor rating plate.
N.B. A pump designed for 400 volt can be used in the 380-415 volt range. A pump designed
for 230 volt can be used in the 220-245 volt range.
Connection of stator and motor conductors
If the pump is not fitted with a connector, connect it in accordance with valid wiring
diagram. Wiring diagrams are included in the workshop manual.
Cable marking on pump cables:
L1, L2, L3 = phase marking at D.O.L start / U1, V1, W1, U2, V2, W2 = stator marking at star-
delta start / F0, F1, F3, F4 = thermal sensor marking / D1, D2 = leakage sensor marking,
must be connected to external relay / GC = ground check marking
The electrical installation shall be inspected by an authorized electrician.
Operation
Before starting:
Check the direction of rotation of the pump (see fi-
gure). At the instant of starting, the pump will jerk
anti-clockwise when viewed from above.
If the direction of rotation is incorrect, transpose two
phases.
m
CAUTION! The starting jerk may be violent. Don't hold the pump han-
dle when checking the direction of rotation. Make sure that the pump
is firmly supported and cannot rotate.
c
CAUTION! Reversal of the direction of rotation on a plug that has no
phase transposing device may be done only by an authorized person.
m
CAUTION! If the built-in motor protection has tripped, the pump will
stop but will restart automatically when it has cooled down.
Service and maintenance
c
CAUTION! Before any work is started, check that the pump is isolated
from the power supply and cannot be energized.
Regular inspection and preventive maintenance will ensure more reliable operation. The
pump should be inspected every six months, but more frequently if the operating condi-
tions are difficult.
For a complete overhaul of the pump, please get in touch with an authorized ABS workshop
or your ABS dealer.
m
CAUTION!
If a cable is damaged, it must always be replaced.
m
CAUTION! A worn impeller often has sharp edges. Take care not to
cut yourself on them.
m
CAUTION! In the event of inward leakage, the oil housing may be pres-
surized. When removing the oil plug, hold a piece of cloth over it to
prevent oil from splashing.
m
CAUTION! J 205 - 604
Two overhead cranes must be used to lay the pump or motor section
on its side safely. When the pump or motor section has been laid on
its side, always secure it with wedges from both sides to prevent it
from rolling away.
End-of-life units can be returned to ABS or recycled in accordance with
local regulations.
GB
Starting
jerk

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

JsJc

Inhaltsverzeichnis