8. Installation/Setup

Installation of the device must be carried out by a specialist familiar with the hazards and the
relevant regulations. Maintenance, operation and commissioning of this device must only be
carried out by qualified persons.
Always observe the safety notes on this as listed above in these instructions and the legal
provisions and requirements of your country for assembly.
The laser must not be inadvertently adjusted, turned or otherwise changed in position after
mounting.
When choosing a location for your device, make sure to avoid impact, vibration, dust, hot and
cold temperatures and dampness. Furthermore, no powerful transformers or motors must be
used close to the device.
When setting up the device, make sure that the power cord is not crushed and cannot be dama-
ged by any sharp edges.
Do not drill or screw additional screws into the casing in order to fasten the device. This may
expose dangerous voltage to touch.
Never operate the device on flammable surfaces or close to flammable objects. Always keep a
distance of at least 1 m to flammable objects.
Observe that the fog exit opening is not pointed at persons, animals or open flame. The escaping
hot steam may cause burns (comply with a safety distance of 0.5 m).
Ensure a sufficient ventilation of the device, maintain a free zone of 0.5 m around the device and
never cover the ventilation openings.
The device must only be operated in locations with an ambient temperature of no more than
30 °C.
Never place the device on an unstable underground. Ensure that it does not fall down and cause
injury.
The operating position of the device is horizontal so that the tank cannot spill when filling the
fog machine and in operation.
The device must be set up out of normal reach. If the device is operated in an elevated location,
make sure no one can enter the space beneath it (danger of slipping and injury through hot fog
liquid and its residues).
During installation or service work, the area below the place of setup must be cordoned off.
The area or equipment of installation or setup must be designed in such a way that it can sup-
port the tenfold rated load for at least one hour without being deformed permanently.
It is also essential that the device is secured by means of a second safety restraint that is inde-
pendent of the actual mounting supports when installing it in an elevated position. No part of
the installation must fall down if the main suspension system fails.
All statutory regulations applicable in the respective country must be observed when installing
and setting up the device.