check for pellet quality
check for overpressure switch, could be off because of dirty smoke outlet. Could a sign
the smoke extractor doesn't work properly
check for the safety thermostat
Solution:
Check the causes.
If the problem persists, contact technical support.
Trouble:
The pellet does not fall into the brazier, because of it:
check for pellet tank being loaded.
check for loading screw motor not being blocked.
check for loading screw is not blocked.
check the main board.
Solution:
Check the causes.
If the problem persists, contact technical support.
Trouble:
Occurs when the general safety thermostat detects a temperature higher than the fixed level
of security set by the manufacturer, because of it:
The chimney may be obstructed
Canvas or different objects laid on the appliances.
Install the appliance in a niche without proper ventilation
Lack of ventilation grids on the coating (inserts and fireplaces).
Thermostat temperature probe defective.
Solution:
Check the causes.
If the problem persists, contact technical support.
To quit the error signal follow the procedure:
1) unscrew protection cup
2) press safety thermostat
button
REMOTE CONTROL
3) screw the protection up.