REMOTE CONTROL
enabled when the buzzer will sound intermittently. If you fail to reset the alarm, the unit will go off in any case, always
displaying the alarm message.
Trouble:
During the working status of the unit, may lack electricity. Upon restart, if the period of the
black-out is very short (< 1 minute), the unit starts in WORK mode, otherwise the alarm is
activated. The display will scroll the following message and the unit goes off.
Solution:
Check the causes.
Await the caming back of the electricity and re-start the appareil.
Trouble:
Refer to smoke probe wiring, because of it:
Check the smoke temperature probe and test it.
Check the smoke probe being correctly positioned at the correct depth.
Solution:
Check the causes.
If the problem persists, contact technical support.
Trouble:
Appliance is getting overheated, because of it:
Check to see if the unit is badly positioned.
Check if any obstruction flues.
Check if you have made your annual cleaning combustion chamber and gas flues by
authorized personnel.
Smoke probe defective or badly positioned.
Solution:
Check the causes.
If the problem persists, contact technical support.
Trouble:
The smoke exhaust fan doesn't work, because of it:
Check encoder wiring and electrical connections.
Check if you have made your annual cleaning combustion chamber and gas flues by
authorized personnel.
Solution:
Check the causes.
If the problem persists, contact technical support.
Trouble:
Burning does not start, because of it:
Check the correct position of the burner and the ash drawer.
Check if the daily cleaning was done though.
Check for pellet in the tank: pellet feeding screw empty
not enough primary air (combustion) because of dirtiness (lack in maintenance)
check for the starting resistance