AIR FAN

8. MODULATION (SET TEMP)

When the room temperature (or the temperature of water in the hydro models) has reached the set value, the heating
power of the heater is automatically brought to the minimum power. Under such conditions, the display shows the
following message.
If the room/water temperature falls below the set (Set temperature), the unit, return to the "Work" and the power
previously set (Set power).
MODULAT

9. STAND-BY MENU 06

If enabled in the menu, standby function allows you to use the unit with a programm STOP-GO. After reaching the
set temperature, (+ 1/2°C of TEMP SET for air device; + 15° C of SET TEMP WATER for hydro device), the machine
starts the shutdown procedure and the display show the following message:
WAIT COOLING
After turning off, the device is paused and the display show the following message:

MODE STAND-BY

If the room temperature goes under 2°C of the pre set (Set temp room) the unit restart.

10. SWITCH OFF THE APPLIANCE

To turn off the unit simply do a long press on the button P4. The display shows the following message:
FINAL CLEANING
The pellets load will stop right away while the other components will be stopped by the respective thermostats. The
product requires approximately 30 minutes to complete cooling. When the unit is cooled appears:
OFF