c) Rechargeable Battery Program „CYCLE"
This rechargeable battery programme serves automatic repeated charging and
discharging of a rechargeable battery. This serves, e.g., to remove memory effects
in NiCd rechargeable batteries. The charge current can be set (250 mA to 2500 mA),
as well as the discharge current (100 mA to 1000 mA) and the number of cycles
(1 to 12).
After insertion of the rechargeable battery into one of the 4 charging chutes, chose the rechargeable
battery programme „CYCLE" with „2" or „8", then push the button „ENTER".
The charging current now flashes at the top of the display; set it with the button „2" or „8".
Push the „ENTER" button. The charging current now flashes in the display; set it with the button
„2" or „8".
Push the „ENTER" button. The number of cycles flashes in the display; set it with the button „2"
or „8" (1....12 cycles are possible).
After confirmation with „ENTER" (or if no button is pushed for more than 5 seconds), the rechar-
geable battery program commences.
The display alternatingly shows the rechargeable battery voltage in volt („Charge Volt"), the
charging or discharging unit in mA („ChargeRate" or „DisChargeRate", depending on whether
the battery is being charged or discharged), the elapsed charging or discharging term in hours/
minutes („Charge Time" or „DisCharge Time") and the charged or discharged energy in mAh
(„Charge Capacity" or „DisCharge Capacity").
When the set cycles were passed, the rechargeable battery will be charged.
After conclusion of the rechargeable battery programme, „DONE" appears in the display and the
discharge capacity of the last cycle; the bottom of the display shows „HIST CYCLE".
Pushing the figure button that belongs to the rechargeable battery chute several times briefly
permits displaying the discharge capacity for each cycle.
The rechargeable battery can now be taken from the charger.
If the rechargeable batters remains in the charger, the charger switches to maintenance
mode. The rechargeable battery is charged with a very low current (about 30 mA) to
maintain the full charge condition.