When you try to connect another thermo-hygrometer of same design to your
smartphone/tablet, the display will open a window.
Select "No" to continue displaying the measurements of the thermo-hygrometer
already connected.
Select "Yes" to connect the new thermo-hygrometer with the app.
If the connection cannot be established, the old thermo-hygrometer remains
connected.
Reset the max/min memory once you have connected a new thermo-hygrometer
with the app (refer to the last line of the table below).
d) Displaying values stored in the memory
• In order to display max/min values, use your finger to swipe across the display of your
mobile device (to the left or right).
- Swipe to the left in order to display the max/min humidity readings.
- Swipe to the right in order to display max/min temperature readings.
• The left side of the display (DAILY) shows the daily maximum/minimum readings. The
readings will be reset daily at midnight.
• The right side of the display (RECORDED) shows the maximum/minimum readings that
have been recorded since the last manual reset (refer to the last line in the table below).
e) Setting up the main screen
• Touch the cogwheel icon in the upper left corner of the display.
• You may then select the functions that you want to display on the main screen. Slide the
controls to ON or OFF to activate or deactivate the respective functions. You may also
select the temperature unit or delete the max/min memory.
• Then touch the "Edit" button in the upper right corner of the display. To the right side of
certain indicators there will be a symbol consisting of 3 horizontal lines. Use your finger
to touch this symbol and slide the respective index up or down to the desired position.
• Then touch the "Done" button in the upper right corner of the display. All settings will
be saved.
Index / function
Description
WBGT
"Wet Bulb Globe Temperature" is a common value for
measuring the heat stress that affects human beings. This
measurement usually also takes wind and solar radiation
into account. As for this product, the calculation is slightly
simplified and based on temperature and humidity only.
Humidex
Humidex is a value especially common in Canada, indicating
what temperature the average person perceives at a current
temperature and humidity. If the display shows a value of
35, then this equals a perceived temperature of 35°C. The
Humidex resembles certain similarities to the heat index.
Heat Index
The heat index is a temperature value indicating the perceived
temperature based on measured temperature and relative
humidity.
Mold Index
The mold index, if at an increased level (orange, red), is a
warning indicating that prevailing temperature and humidity
might promote mold growth, especially inside buildings.
Flu Index
The flu index indicates whether airborne transmission of
influenza virus is likely (red) or less likely (yellow) to occur at
the prevailing temperature and humidity.
Fahrenheit / Celsius
Select whether to display the temperature in °C (degree
Celsius) or °F (degree Fahrenheit).
Recorded MAX / MIN
Touch the red "CLEAR" button in order to delete all saved
max/min values. A window will open prompting you to confirm
this function. Touch the green "Yes" button to permanently
delete all values. Or cancel the procedure by touching the red
"Cancel" button.
Next to the indices there are symbols or warning triangles displayed in different
colors.
Green indicates a comfortable situation, except for the WBGT index. In latter
case, the green warning triangle indicates that caution must be exercised.
Red indicates a situation that stipulates a high risk and requires immediate
measures to be taken.
f) Assembly and installation
• The product can be installed at a suitable location using the stand (6). The installation
surface must be horizontal, stable, flat and of adequate size.
• There are two holes on the back of the stand for mounting the product to a wall.
Do not install the product near radiators or similar.
Avoid direct sunlight and drafts (e.g. near windows or doors).
g) Replacing the batteries
• The display will show a warning before the batteries are completely empty.
• If the batteries are already fully discharged, there will also be a warning displayed and the
user interface appears semitransparent.
• In both cases, replace the batteries as described above and reconnect the product to
your smartphone/tablet.
h) Bluetooth
disconnected
®
• If Bluetooth
gets disconnected for 3 minutes, the user interface appears semitransparent
®
and a warning pops up.
• Check the Bluetooth
function of your smartphone/tablet.
®

Maintenance and cleaning

• Apart from occasional cleaning, the device is maintenance-free. To clean the device, use
a soft, anti-static and lint-free cloth.
• Do not use any abrasive or chemical cleaners.

Declaration of Conformity (DOC)

We, Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that
this product conforms to the fundamental requirements and the other relevant regulations
of the directive 1999/5/EC.
The Declaration of Conformity for this product can be found at www.conrad.com.
Disposal
a) Product
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the relevant
statutory regulations.
Remove any inserted (rechargeable) batteries and dispose of them separately
from the product.
b) (Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/
rechargeable batteries. Disposing of them in the household waste is prohibited.
Contaminated (rechargeable) batteries are labelled with this symbol to indicate
that disposal in the domestic waste is forbidden. The designations for the heavy
metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on
(rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your
municipality, our stores or wherever (rechargeable) batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Power supply ........................................... 2 x 1.5 V/DC, type AAA
System requirements ............................. Apple iOS: iPhone 4S/5/5C/5S/ iPad3/4/Air/mini,
Range ........................................................ max. 20 m (open area)
Dimensions (W x H x D).......................... 35 x 96 x 15 mm
Weight ....................................................... 25 g
Temperature
-40 to +70 ºC
Measurement range
±1 ºC (for 0 to +40 ºC)
±2 ºC (for -20 to -0.1 ºC and
Accuracy
±3 ºC (for -40 to -20.1 ºC)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE.
iPod Touch (5. generation) with Bluetooth
Humidity
5 – 99 %
±5 % (for 30 – 80 %)
±10 % (for 0 – 29.9 % and
+40.1 to +70 ºC)
80.1 –99 %)
4.0
®
V1_0714_02-ETS-Mkd

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis