7. Installation

Assembly and installation of the device must be carried out by a specialist familiar with the hazards
and the relevant regulations. Maintenance, operation and commissioning of this device must only
be carried out by qualified persons.
When choosing a location for your device, make sure to avoid impact, vibration, dust, hot and cold
temperatures and dampness. When operating a fog machine, ensure that the LED effect light is not
directly exposed to the fog jet. Furthermore, no powerful transformers or motors must be used close
to the device.
Never cover the device. Make sure when mounting with other equipment that there is sufficient venti-
lation. Maintain a sufficient distance to other devices and walls. Never install the effect light in direct
proximity of heat sources. Do not point any strong spotlights or light sources towards the device.
This may cause overheating (danger of fire!).
Do not drill or screw additional screws into the casing in order to fasten the device. This may ex-
pose dangerous voltage to touch.
The device must be mounted out of normal reach.
Illuminated objects must be at least 0.5 m away from the device's light emission source. Easily
flammable materials such as decorative fabrics must also have a distance of at least 0.5 m to the
device. Otherwise, such objects may catch fire!
When mounting the product, make sure that the power cord is neither jammed nor damaged by
sharp edges.
During installation or service work, the area below the place of installation must be cordoned off.
The installation surface or mounting fixture needs to be designed in a way that it can take 10 times
its load capacity for at least 1 hour without permanent damaging deformation.
It is also essential that the device is secured by means of a second safety restraint that is inde-
pendent of the actual mounting supports when installing it in an elevated position. No part of the
installation must fall down if the main suspension system fails.
Observe all relevant regulations of your country when installing the device.
Acceptance test (in case of industrial/public use):
Before first use and after any significant modifications, the installation (including the electrical connections)
must be inspected by an official expert.
A yearly inspection by an expert is required.
• Attach the effect light to the ceiling or on a suitable crossbeam with the mounting bracket. There is an attachment
hole in the mounting bracket for mounting with a screw. The assembly must never swing freely. Use assembly
material suitable for the assembly area and for bearing the effect light load.
• Set the desired inclination angle and tighten the two fastening screws well to the assembly bracket.
Many provisions and requirements must be observed for commercial or public use. They are only
described here in excerpts. You as the operator are responsible for ensuring that they are complied
with at installation and operation.