CAUTION
Intended operation not ensured if
installed incorrectly. A fan not installed
correctly may result in operation not as
intended.
 Operation is only permitted with
protection against accidental contact on
both sides in accordance with EN ISO
13857, e.g. use protective grille SGR 100
or shutter AP.
 In particular, note the information on
ventilation channels and sound deadening.
DANGER
Risk of injury and health risk when
using accessory elements which have
not been approved.
 The unit may only be operated with
original components.
 Modifications and alterations are not
permitted and release the manufacturer
from any guarantee obligations and liability.
DANGER
Risk of death from carbon monoxide
when operating with air-ventilated
fireplaces.
When operating with air-ventilated
fireplaces and in "air extraction" installation
position, a sufficient fresh air supply must
be ensured. The maximum permitted
pressure difference per living unit is 4 Pa.
The consent of a professional chimney
sweep is needed in all cases.
WARNING
Exercise caution when handling
packaging materials.
 Observe applicable safety and accident
prevention requirements.
 Store packaging material out of the
reach of children.
6. Safety instructions │ UK
DANGER
Danger of electric shock from operating
with the unit not fully mounted. Electric
components are a potential source of
electric shock.
 Before taking off the motor cap,
shut down all supply circuits (switch off
mains fuse), secure against being
accidentally switched back on and position
a visible warning sign.
 Only operate the fan when it is
completely installed.
DANGER
Failure to observe the relevant regulations
results in a risk for electrical installations.
 Before installing the electrics, shut down
all supply circuits, deactivate the mains
fuse and secure it so it cannot be switched
back on. Attach a warning sign in a clearly
visible place.
 Be sure to observe the relevant regula-
tions for electrical installation; e.g. EN
50110-1, in Germany this is particularly
VDE 0100, with the corresponding parts.
 A mains isolation device with contact
openings of at least 3 mm at each pole is
mandatory.
 Only connect unit to a permanently
wired electrical installation with NYM-O /
NYM-J, 3 x 1.5 mm² cables.
 The units may only be operated using
the voltage and frequency shown on the
rating plate.
 The degree of protection stated on the
rating plate is only guaranteed if installation
is undertaken correctly (horizontal
installation position) and if the connection
cable is correctly guided through the cable
grommet. The grommet must tightly seal
the cable sheathing.
9