Temperature Tables - Endress+Hauser Gammapilot M FMG60 Sicherheitshandbuch

Profibus pa, foundation fieldbus
Vorschau ausblenden Andere Handbücher für Gammapilot M FMG60:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

XA00333F-D

Temperature tables

14
1
2
å
2
A
Version 1
Use small capacitors (e.g. 1 nF, 1500 V, dielectric strength, ceramic).
Total capacitance connected to the screen may not exceed 10 nF.
B
Version 2
1
Terminating resistor
2
Distributor/T box
3
Screen insulated
4
Supply unit/Segment coupler
5
Potential equalization (secured in high degree)
6
Field device
Ambient temperature
Detector without water cooling or
detector with water cooling out of operation:
• Devices with NaJ crystal scintillator:
• Devices with PVT plastic scintillator:
Detector with water cooling in operation:
At the pipe housing
(within the water cooling):
• Devices with NaJ crystal scintillator:
• Devices with PVT plastic scintillator:
At the compartment housing:
Maximum surface temperature T
Detector without water cooling or
detector with water cooling out of operation:
Detector with water cooling in operation:
• At the pipe housing (within the water cooling):
• At the compartment housing:
2
6
6
–40 °C  T
 +60 °C
a
–40 °C  T
 +60 °C
a
–40 °C  T
 +60 °C
a
–40 °C  T
 +60 °C
a
–40 °C  T
 +80 °C
a
T80 °C at T
= +60 °C
a
T80 °C at T
= +60 °C
a
T80 °C at T
= +75 °C
a
T85 °C at T
= +80 °C
a
Gammapilot M
3
A
4
C
B
4
5
Erdung
3
2
4
1
FMG60_01
å
3
1
Pipe housing
2
Compartment housing
3
Terminal compartment A
4
Terminal compartment B