Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Safety; Installation; Install The Pump; Connect The Suction Line - AL-KO HW 600 ECO Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Installation

3.1 Electrical safety

DANGER!
Danger from contact
with live parts!
A defect in the pump or the
extension cable can result
in serious injury!
Disconnect the con-
nector plug from the
mains immediately.
Connect the device via
an earth leakage circuit
breaker with a rated
leakage current of < 30
mA.
The pump may not be oper-
ated while people are in the
pool or pond.
The mains voltage at your loc-
ation must comply with the in-
formation regarding mains
voltage in the Technical Data.
Do not use any other supply
voltage.
The appliance must only be
operated on electrical equip-
ment in accordance with DIN/
VDE 0100, parts 737, 738 and
702. For fuse protection, a cir-
cuit breaker of 10 A and an
earth leakage circuit breaker
with a rated leakage current of
10/30 mA must be installed.
469929_a
Only use extension leads ap-
proved for outdoor use with a
minimum cross-section of
2
1.5 mm
. Always fully unwind
cable drums.
Damaged or fragile extension
cables may not be used.
Check the condition of you
extension cable prior to
every use.
4 INSTALLATION
4.1

Install the pump

1. Prepare a level and sturdy installation loca-
tion.
2. Install the pump horizontally and where it will
not be flooded.
The pump must be protected from rain and
direct water jets.
NOTE
In day-to-day operation (automatic
mode), suitable measures must be taken
to exclude the possibility of flooding of
rooms as a result of malfunctions in the
pump.
4.2

Connect the suction line

NOTE
We recommend the installation of flex-
ible lines at the pump inlet to prevent
mechanical pressure or tension being
exerted on the pump.
1. Select the length of the suction line such that
the pump cannot run dry. The suction line
must always be at least 30 cm under the wa-
ter surface.
2. Connect the suction line. Ensure that the
connection is tight, but take care not to dam-
age the thread.
21

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hwi 600 eco

Inhaltsverzeichnis