Herunterladen Diese Seite drucken

Service Settings; Confi Gurations; Clock; Aromatherapy Control - HOESCH SenseSation Montage- Und Bedienungsanweisung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3

04.08 Service settings

In the are of "Service" you can set confi guration, clock, aroma control and manual decalcifying.
Using
and
buttons you can use menu functions. With "menu" button, you enter sub-menu, and with "exit" button
you return back to service menu.
04.08.1 Confi gurations
By pressing the [menu] button you can enter the sub items "contrast" and "language". They can be than selected using
and
buttons.
Display contrast can be adjusted from 0-40 by using [-] and [+]button. The factory default value is 20.
Language can be selected by using [-] and [+]button. You can choose one of the following language versions: German,
English. French, Dutch, Spanish, Italian, Polish, Russian or Chinese. The factory is set to German language version.

04.08.2 Clock

Under the menu item "clock" you can set both "time" and "12 hour clock".
In order to set the time, choose the required function with
[-] and [+]button.
To select or cancel 12-hour format, use the
button.

04.08.3 Aromatherapy control

Aromatherapy control submenu (impulse time, impulse duration, minimal temperature required) is chosen
with
and
buttons which are selected by pressing [OK] button. All settings can be adjusted with [-] and [+] button.
Impulse time can be regulated from 0 to 600 seconds, factory setting is 300 seconds. Impulse duration can be regulated
from 100 to 5000 ms, factory setting is 1000ms. Minimal temperature required can be regulated from 30°C to 50 °C,
factory setting is 30°C.

04.08.4 Anti-calc function

Please do not open the fi lling opening during steam bath! For safety, we
recommend to wait at least 30 minutes after the end of steam bath to cool
the cabin.
With the menu item "Decalcifying" in the service settings, you can start the decalcifying
process manually at any time. There you select the buttons
decalcify the device at this time or not and confi rm with [OK] button.
250 ml of a descaling liquid (e.g. HOESCH special descaler, no. 692101) should be used for
decalcifying.
Anti-calc function
After 20 hours of work the device automatically calls for anti-calc function start up. The
following message appears in the display: Do you want to start anti-calc function?
You can select "Yes" to start the anti-calc process or "No" to start this function just after the steam bath. Before starting
the next steam bath the anti-calc process must be started, otherwise, the system will not allow to start the steam function
indicating the necessity to run the anti-calc function.
Manual decalcification
Please, enter "Service" subsection choosing menu and then press the "anti-calc" button and select "menu".
Pressing the
and
button, you can choose if you want to start decalcifi cation process and confi rm it
with [OK] button.
and
buttons and then, set hour and minutes by using
and
buttons then choose appropriate subsection and confi rm with [ok]
and
if you want to
GB
MAX 500ml
17

Werbung

loading

Diese Anleitung auch für:

He4