Technical Data

HGG 110 NIRO
Nominal heat load Qu:
Max. (Hi) 11,2 kW
Air throughput:
500 m
3
/h
Connection:
G 30: 815 g/h P/B
Type of gas:
commercially available
propane (DIN 51622)
Commercially available
butane (DIN 51622)
Operating pressure P:
300 m bar
Mains power supply:
230 V ~ 50 Hz 38 W
Trouble Shooting
Problem
Cause
Motor doesn't start
No electricity
Piezo doesn't ignite
Electrode incorrectly adjusted
No gas at burner
- Gas valve is closed
- Gas cylinder is empty
- Gas hose or connection leaks
Burner ignites, flame is
- The thermoelement was not
extinguished as soon as the gas
-
warm enough
valve is released
- The safety thermostat
-
-
switches off
Burner goes out while in use
- Gas flow too high
- Air input too low
Important!
Have repairs carried out only by specialist workshops or ISC.
15.06.2004
11:46 Uhr
Seite 11
HGG 171 NIRO
Max. (Hi) 17 kW
500 m
3
/h
G 30: 1430 g/h P/B
commercially available
propane (DIN 51622)
Commercially available
butane (DIN 51622)
300 m bar
230 V ~ 50 Hz 38 W
Remedy
- Check electrical outlet
- Check mains cable
Check electrode and precisely
set according to diagram
- Open valve
- New gas cylinder
- Locate point of leak with soap
-
foam and repair
- Repeat ignition procedure
-
while pressing in the gas
-
valve knob
- Allow the heater to cool for a
-
few minutes and reignite
- Have the pressure regulator
-
inspected and replace if
-
necessary
- Check the suction grid and
-
clean
- Inspect ventilator