Ventilation
Caution:
The heater must only be used in
well ventilated areas (heater is
not intended for use in enclosed
spaces). The continuous
presence of persons in these
rooms is forbidden. If more than
one heater is used in one room,
be sure to provide for
correspondingly more fresh air
circulation.
Maintenance
Always first unplug the heater
before any maintenance or
repairs.
Disconnect the gas hose from
the gas cylinder.
Regularly check that the gas
hose and its screw
connections are sealed. Only
Q1 On/Off switch
original replacement parts and
F1 Safety thermostat
hoses must be used. Hoses
M1 Fan motor
must meet the specifications in
Y1 Thermoelectric ignition fuse
DIN 4815 Section 2.
Y2 Safety solenoid valve
Adjustment of the ignition
B1 Thermoelement
electrode should be checked
B2 Piezo ignition
as shown in the adjacent
B3 Ignition electrode
diagram.
B4 Burner
10
15.06.2004
11:46 Uhr
M 1
B 4
B 1
M
B 3
Y 2
/W
E
v
Q 1
L 1
N 1
Y 1
F 1
Seite 10