1.8.4
Burner assembly
1
Gastrain (1").
2
Diapharagma burnerair supply.
Aluminium pipe ∆ P-measurement.
3
4
Adjustment flue recirculation.
5
Burnerhousing.
6
Flue fan motor.
1.8.5
A Ignition electrode
With the ignition transformer a spark is formed
between the ignition electrode and the cone of the bur-
ner. In this way the gas/air mixture is ignited. It is
important that the preset opening between the ignition
electrode and the burner is 3 mm.
B Ionisation electrode
This type of security uses the electrical conductance of
the flame. It is important that the ionisation electrode
does not make contact with the mass.
1.8.6
Gasvalve
A On/Off version
B High/Low version
1 Measuring point gasinletpressure
2 Measuring point burner pressure
3 Adjusting high position
4 Adjusting low position
5 Protection hood
6 Adjusting burner pressure
Description of the equipment Gerätebeschreibung
Brennerzusammenstellung
1
Gasregelstrecke.
2
Blende Verbrennungsluft
Aluminiumrohr ∆ P-Messung.
3
4
Einstellung Abgasrezirkulation
5
Brennerbehausung.
6
Motor Abgas
A Zündelektrode
Mit dem Zündtransformator wird zwischen der
Zündelektrode und dem Konus des Brenners ein Funke
gebildet. Damit wird das Gas-/Luftgemisch gezündet.
Es ist wichtig, daß die vordere Öffnung zwischen der
Zündelektrode und dem Brenner 3 mm beträgt.
B Ionisationselektrode
Dieser Sicherungstyp nutzt die elektrische Leitfähigkeit
der Flamme. Es ist wichtig, daß die Ionisations -
elektrode keinen Massenkontakt hat.
Gasmagnetventil
A An/Aus Ausführung (2x)
B Magnetventil Zweistufig (2x)
1 Meßpunkt Gasvordruck
2 Meßpunkt Brennerdruck
3 Einstellung hoch
4 Einstellung Tief
5 Schutzkappe
6 Einstellung Brennerdruck
1.8