10. refit the ventilation grille, fixing the
screws;
11. reassemble the lower door;
12.reassemble the middle hinge on the
opposite side;
13.replace the upper door.
14.In your documentation bag you will
find the upper hinge necessary to
make the reversibility. Please mount it
in their relevant place.
1. 5 Dismantle the handles by sliding the handle-cover, by unscrewing its
side and middle screws and reassemble them on the opposite side. Cover
the holes left open with the plugs contained in the documentation pack.
Attention:
all the screws are properly tightened and that the magnetic seal adheres to the
cabinet. If the ambient temperature is cold (i.e. in Winter), the gasket may not
fit perfectly to the cabinet. in that case, wait for the natural fitting of the gas-
ket or accelerate this process by heating up the part involved with a normal
hairdrier.

Electrical connection

Before initial start-up, refer to the appliance rating plate to ascertain if sup-
ply voltage and current values correspond with those of the mains at the
installation location.
e.g.:
(i.e. 230 to 240 volts alternating current, 50 Hertz)
The rating plate is inside the appliance on the left.
A correctly installed, earthed socket is required for the electrical supply. The
supply must have a fuse rating of at least 10 Amps.
If the socket is not accessible once the appliance is built in, the electrical
installation must include suitable means of isolating the appliance from the
mains (e.g. fuse, cut-out, current trip or similar with a minimum contact
separation of 3 mm).
Attention: The mains connection cable may only be replaced by a skilled
electrician. Please contact your dealer or our customer service department
for repairs.
Prior to Initial Start–Up
• Please clean the appliance interior and all accessories prior to initial start-
up (see section: "Cleaning and Care").
28
After having reversed the opening direction of the doors check that
AC
230 ... 240 V
230 ... 240 V~
50 Hz
50 Hz or