Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

BA-120/240/480 DP

REAR PANEL CONTROLS

1. AC POWER
This is AC power cable, please connect power plug after main
power switch "OFF".
2. AC POWER REMOTE
This is a terminal of AC power remote control for power supply
to the equipment under AC mains "OFF".
3. DC POWER TERMINALS
This is terminals for DC24V battery power supply, when unex-
pected AC Power failure.
IMPORTANT NOTICE: For the use the cable
length within 4m/5.0mm² diameter.
4. GROUND / LIFT SWITCH
This switch is for grounding between circuit ground and chas-
sis ground to avoid problems like an electrical potential diffe-
rence.
5. FD-20 SLOT
This is slot for installation of FD-20.
6. AMP OUTPUT TERMINALS
These Terminals are for connection of speaker lines to
deliver power output to speakers.
25V
Model
(5.2Ω)
BA-120 DP
(2.6Ω)
BA-240 DP
(1.3Ω)
BA-480 DP
RÜCKSEITE
1. Netz - Kaltgerätestecker
Netzanschluss für das mitgelieferte Netzkabel. Beim einste-
cken der Netzspannung sollte das Gerät ausgeschaltet sein.
2. Netz - Ferneinschaltung
Dieser Kontakt dient zur Ferneinschaltung der Endstufe
bei ausgeschaltetem Netzschalter.
3. DC 24 V Notstromversorgung
24 V Gleichspannungsanschluss von der Notstromversor-
gung.
WICHTIGER HINWEIS: Die maximale Kabellän-
ge sollte 4m nicht überschreiten, und der Durch-
messer sollte mindestens 5 mm² sein.
4. GROUND / LIFT Schalter
Mit diesem Schalter können Sie die Gehäusemasse von der
Schaltungsmasse trennen. Somit kann ein Brumm, welcher
durch Potentialunterschiede entstehen kann, vermieden wer-
den.
5. FD-20 Einschubfach
Hier wird das FD-20 Modul eingesetzt.
6. Lautsprecherausgänge
Anschluss für die Lautsprecherleitungen.
Wichtig: Die Gesamtimpedanz darf den unten angegebenn
Wert nicht unterschreiten!
50V
100V
(20.8Ω)
(83.3Ω)
(10.4Ω)
(41.7Ω)
(5.2Ω)
(20.8Ω)
5

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ba-240dpBa-480dp

Inhaltsverzeichnis