8. Then screw in the shower plate (item no. C519900102) and the shower holder.
9. In order to ensure that the group gasket is inserted properly, carefully clamp a portafilter without filter into the
brew group.
Follow the steps as indicated below:
1.
Brew group at the beginning
4.
Remove the thin gasket of the shower
tray
7.
Clean the groove before inserting the
new group gasket
The steam nozzle is blocked
Clean the holes of the steam nozzle carefully with a needle or with a paper clip.
For this purpose, the steam nozzle may be unscrewed as well.
Afterwards replace the steam nozzle.
2.
Remove the countersunk screw in the
middle of the brewing unit
5.
Now the group gasket can be
removed.
8.
Insert the new group gasket with the
rounded side facing upwards
22
3.
Remove the shower screen and the
shower plate
6.
Remove the group gasket with a
screwdriver
9.
Replace the gasket of the shower tray
(see point 4) and the shower plate